9-  30 Service Guide  LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497  723984- 2005-05-11 225553-040
9.6  Parameters
• Press and hold S18 while turning S17 to “ON” position.
• Press and hold S18 until P = parameters is displayed.
• You have now selected P = parameters and the symbol “C” is lit as 
an indication of what is now shown in the display.
• Press L1 up or down and scroll to the parameter you want to change 
or view.  
• Press S18 once to access the parameter.
• Press L1 up or down to specify the parameter value.
• Press S18 once to confirm the change.
• Turn S17 to the off position.
You have now changed the parameter and the new setting will come 
into force the next time you start the machine. 
NOTE: 
Truck handling
When you change specific truck parameters, the truck’s driving char-
acteristics are also changed.
Do not change any parameters unless you really know what you are 
doing.
9.6.1 Operator parameters
Parameter Description Unit Min. Max. Step Std. Description
01 Speed, Turtle 
button
% 40 100  5 100 Speed, Turtle button
10: slow speed
100: maximum speed.
02 Max. speed % 40 100 5 100 Max. speed
10: slow speed
100: maximum speed
03 Acceleration 10 100 5 50 10: slow acceleration
100: maximum accelera-
tion
04 Braking in neu-
tral mode
5 100 5 50 Specifies motor braking 
once the lever is put into 
neutral.
5: weak braking power
100: maximum breaking 
power
05 Logout 1min 0 20 1 20 The time it takes for the 
truck to switch off when 
the keypad is used. The 
time counts down from 
the moment the last 
power-consuming unit is 
used. 
 
Value = 0 gives 4 hours.
In steps of 1
A
B
C
DE