9- 32 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
9.6.3 Service parameters
Connect the CAN key to X41.
Press and hold S18 while turning S17 to “ON” position.
Press and hold S18 until P = parameters is displayed.
You have now selected P = parameters and the symbol “C” is lit as
an indication of what is now shown in the display.
Press L1 up or down and scroll to the parameter you want to change
or view.
Press S18 once to access the parameter.
Press L1 up or down to specify the parameter value.
Press S18 once to confirm the change.
Turn S17 to the off position.
You have now changed the parameter and the new setting will come
into force the next time you start the machine.
NOTE:
Truck handling
When you change specific truck parameters, the truck’s driving char-
acteristics are also changed.
Do not change any parameters unless you really know what you are
doing.
Parameter Description Unit Min. Max. Step Std. Description
10 PIN-code 0 9999 1 1
Facility for specifying up to 10
PIN codes (10 different drivers).
14 Crawling
speed
-10 10 1 0 The amount of power the mon-
itor should emit when you
reach the first speed sensor
can be specified here.
-10: low speed for the first
speed sensor.
10: high speed for the first
speed sensor
15 Non-config-
urable option
0 to 9
See “Option parameters” on page 34, Servicemanual
16 Configurable
option #1
See “Option parameters” on page 34, Servicemanual
17 Configurable
option #2
18 Configurable
option #3
19 Configurable
option #4
20 Hour meter
option
1 5 1 2 Select hour meter.
21 Battery size 1 20 1 5 Selection of battery size.