Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 9- 43
Recommendation on parameter setting for
valve-controlled batteries (VRLA)
WARNING !
The service life of the battery will be reduced if the value of parameter
21 is set at too high a value. The standard setting of parameter 21 is
set for normal truck handling. Other applications may require a differ
-
ent setting of parameter 21. Check that the parameter setting is the
correct one using the instructions below.
Parameter 21 Battery size
LWE180, LWE200,
LPE200-6
Battery size
LPE200-8
Less discharge
Greater dis-
charge
1
2 260Ah - 320Ah
3 190Ah - 250Ah
4 120Ah - 180Ah 260Ah - 320Ah
5 190Ah - 250Ah
6 120Ah - 180Ah
7
8
9
10
11
12
13
14
15
16
17
18
19