5- 4 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Preventive maintenance – P2 LPE 240
Maintenance schedule
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
1= Connections are tightened for the first time after 80 hours and then
every 1000 hrs/ 12 months.
2= Mounting bolts are tightened after 80 hrs/1 month to 45 Nm.
3= Check for leakage in connection with the first oil change.
4= The oil is changed for the first time after 80 hrs/1 month and then
every 3000 hrs/36 months.
5= The oil is changed and the filter cleaned for the first time after 80 hrs/
1 month and then every 1000 hrs/12 months.
6 = If the truck goes into a refrigerated environment or other harsh envi-
ronment, the point is addressed at more frequent intervals.
When points with higher time intervals are addressed, the points with
shorter time intervals should also be addressed unless otherwise stat
-
ed above.
5700 Electronic card
5700.1 Clean the electrical panel C
5700.2 Check the connectors and cables
T
I
I
5700.3 Check all segments on the display I
6100. Hydraulic system
6100.1 Check for leakage from hoses and couplings I
6100.2 Check for wear to the hoses I
6100.3 Check the tank I
6100.4 Check that the oil level is correct I
6100.5 Change the oil and clean the filter
L
5
L
6600. Lift cylinders
6600.1 Check for leakage I
6600.2 Check the mountings I
6680 PowerTrak
6680.1 Check for any damage, cracks on the Power-
Trak springs
I
6680.2 Grease the ground pressure spring's guides C/L
I: Inspect, correct and replace if necessary. T: Tighten C: Clean L: Lubricate
M: Measure, correct if necessary
Pos.
no.
Work to carry out
Interval in hours - may vary due to ap-
plication
5 20 80 500 1000 3000
Interval in days/weeks/months - may
vary due to application
1d 1w 1m 6m 12m 36m