Electrical System – 5000 LWE 180/200 LPE 200
Error codes
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 9- 19
Code C28
Description Emergency switch caution
Possible error
cause
The emergency switch has been activated.
No current to the travel regulator, input. A1/16.
Action 1. Check fuse F51.
2. Check the emergency switch.
3. Check the cables from the battery and the bat-
tery contacts.
4. If PTC resistor R1 is very hot, remove the bat-
tery contact and allow the resistor to cool.
Restart.
Code C29
Description Service warning
Possible error
cause
Time for service.
The service counter has not been reset since the
last service.

Table of Contents