CLRV lift control valve Product description
20/92
300−I−9010212−E−10/08.08
1.4 C−DELCON electronic card
The C−DELCON controls the oil flow − and therefore the lift’s travel pro-
file − in accordance with a preset curve.
Attention
Electrostatic discharge (ESD)
The C−DELCON can be damaged by incorrect handling.
Always keep the DELCON in its ESD protective bag and only hold it by
the spacer studs (4).
300−2−10012279
6
1
2
3
5
4
Legend 1
2
3
4
5
6
Nameplate
Label with Test number
Label with description of LED functions
Spacer studs M2.5x10
Label with Demand values
RESET button (restarts the program in the C−DEL-
CON electronic card)
1.4.1 Factory settings
S Maximum UP and DOWN speeds
S Slow speed set to 5−10 % of maximum speed
S Acceleration/deceleration set to mid−range value
S Inspection travel speed set to 50 % of maximum speed