CLRV lift control valve Maintenance
90/92
300−I−9010212−E−10/08.08
6.2 Operating materials and aids
Hydraulic oil (code) Viscosity
[mm2/s] (cSt)
Permissible
temperature range
to DIN 51525 to ISO 6074 at 40°C min. °C max. °C
H−LP 32 ISO VG 32 32 1 42
H−LP 46 ISO VG 46 * 46 8 50
H−LP 68 ISO VG 68 68 15 59
H−LP 100 ISO VG 100 100 21 60
Shell Tonna S32 32 1 42
Shell Tonna S68 68 15 70
* This oil can be used in most applications. For frequently−used passenger lifts, the thicker VG 68 oil should be used.
The type of oil actually used to fill the system must be recorded by the lift manufacturer in the designated field on the
nameplate of the submersed motor/pump power unit.
Tested and approved hydraulic fluids with
biodegradable characteristics
Type Panolin HLP
32/46 Synth
HF−E 46 Rivolta
S.B.H.23
Avia Syntofluid
F 32 or 46
Megol
HEES46
Supplier
Panolin AH
Medetswil (CH)
Shell
Bremer+Leguil
GmbH
Avia
Avia−Kühmichel
Liqui Moly GmbH
Ulm (D)
Viscosity 40°C
mm@/s
(cSt)
32/46 46 46 32/46 48
Base Ester Ester Ester Ester Ester
Water−hazard class nwg/1 1 nwg nwg 1
Biodegradability >90% >90% >97% >90% >90%
Flashpoint °C 240 210 240 310 320
(Water hazard classified in accordance with the German standard dated 1999)
nwg = not hazardous to waters