C−LRV lift control valve Product description
28/92
300−I−9010212−E−10/08.08
1.5.2 Technical data
300−1−10008856
110
100
100
110
M4
812
151.7
Weight 0.675kg
Mains voltage NTA−2/115 100/(110)115/120VAC
NTA−2/230 220/230/240VAC ±10%
NTA−2/400 380/(400)415/440VAC
Frequency 50/60Hz ±10%
Power consumption 20W during travel,
approx. 8W at standstill
EMC standards EN−50081, EN−50082, EN−50011/22, IEC 1000−4
Protection class IP 00
Relay contacts
l
min
= 10mA
l
max
= 3A
Command inputs
Command present U < 2.5V
Command current ≈ 6mA
Command not present U > 10V