C−LRV lift control valve Operating controls and indicators
39/92
300−I−9010212−E−10/08.08
Password
The C−DELCON’s parameters and functions can be password−protected.
The password consists of four numbers. Password 0000" means that
password protection is not activated (this is the factory setting).
The password is entered one number at a time:
S Increase the value with the + key, decrease it with the − key
S With ↑ or ↓ key, change to the adjacent number
S Press ↑ and ↓ keys simultaneously to save the number
If a password has been set, the user must login in order to change para-
meters. The user logs in by entering the password. The user can logout
at any time, but will be logged out automatically after 8 hours at the
latest.
Important: If an attempt is made to change a password−protected para-
meter, the message not allowed" is displayed.
Important: If the power supply unit is wired into the safety circuit, the
user is not logged out automatically