EasyManuals Logo

Bucher C-LRV Series User Manual

Bucher C-LRV Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
CLRV lift control valve Operation
76/92
300−I−9010212−E−10/08.08
5.1.4.3 Null point / Hall sensor menu (3)
S Displays the current feedback value
5.1.4.4 Information menu / Commands" (4)
Setting "Language/Sprache"
S Selection of the user language
S Possible languages
German
English
French
Italian
S Standard: German
Command "Load parameter"
S Overwrites the current parameters with the internally−saved
parameters
S Possible parameter sets
Factory (factory settings)
User
Command "Save parameter"
S Saves the current C−DELCON parameters as the User parameter set
Setting "Password"
S Prevents unauthorised changes to parameters
S Consists of any 4 numbers
S Password 0000" means: protection not activated (factory setting).
Command "Delete errors"
S Deletes the error list
Command "Pipe rupture"
S Simplified test procedure for the pipe−rupture valve, see page 62