Safety and general instructions 2
Logamax plus GB162-80 kW/100 kW - Subject to modifications resulting from technical improvements!
7
2 Safety and gen eral instructions
section 8 Safety and general instructions
Please observe these instructions in the interest of your own
safety.
Designated use
The boiler was designed for heating water for a central heating
system and generating domestic hot water.
The boiler is suitable for connection to fully pumped, sealed
water systems ONLY.
The boiler can be installed either as a single system or as part
of a multiple system (cascade system) with a maximum of 8
boilers connected together.
These boilers may not be installed in places over 4,000 ft. above
sea level.
Hazard definitions
The following defined terms are used throughout the documen-
tation to bring attention to the presence of hazards of various
risk levels. Notices give important information concerning the
operation of the product.
DANGER
Indicates the presence of hazards that will cause
severe personal injury, death or substantial property
damage.
WARNING
Indicates the presence of hazards that can cause
severe personal injury, death or substantial property
damage.
CAUTION
Indicates presence of hazards that will or cause
minor personal injury or property damage.
CAUTION
Risk of electric shock.
Indicates presence of hazards due to electric shock.
NOTICE
Indicates special instructions on installation, opera-
tion or maintenance that are important but not
related to personal injury or property damage.
The following instructions must be observed
The boiler must only be used for its designated purpose,
observing the Installation Instructions.
Only use the boiler in the combinations and with the accesso-
ries and spares listed.
Maintenance and repairs must only be carried out by trained
professionals.
You are only permitted to operate the condensing gas boiler
with the combustion air/flue gas system that has been specif-
ically designed and approved for this type of boiler.
Please note that local approval of the flue system and the
condensate connection to the public sewer system may be
required.
If boiler installation is provided as replacement heater,
DO NOT connect new boiler venting to an existing vent
system, if it is shared with other appliances.
You must also observe:
The local building regulations stipulating the installation rules
at the time of installation.
The local building regulations concerning the air intake and
outlet systems and the chimney connection.
The regulations for the power supply connection.
The technical rules laid down by the gas utility company con-
cerning the connection of the gas burner fitting to the local
gas main.
The instructions and standards concerning the safety equip-
ment for the water/space heating system.
The Installation Instructions for building heating systems.
The boiler must be located in an area where leakage of the
tank or connections will not result in damage to the area adja-
cent to the boiler or to lower floors of the structure. When
such locations cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed under the
boiler. The pan must not restrict combustion air flow.
The boiler must be installed such that the gas ignition system
components are protected from water (dripping, spraying,
rain etc.) during boiler operation and service.
The boiler must not be installed on carpeting.
Do not restrict or seal any air intake or outlet openings.
If you find any defects, you must inform the owner of the sys-
tem of the defect and the associated hazard in writing.