ROFSNOITCURTSNIECIVRES
MODEERF
YCNEICIFFEHGIHGNISNEDNOC
TNEVTCERID
RELIOBRETAWTOHDERIF-SAG
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage,
injury, or loss of life. For assistance or additional information, consult a qualied installer, service agency or the
gas supplier. This boiler requires a special venting system. Read these instructions carefully before installing.
101008-01R2-7/07

Other manuals for Burnham FREEDOM

Questions and Answers

  • R
    Ryan OliverJul 31, 2025
    Why is the display panel blank but fan running on my Burnham FREEDOM Boiler?
    • J
      Jessica RogersJul 31, 2025
      If the display panel on your Burnham Boiler is blank but the fan is running, it could be due to a loose 120VAC connection in the wiring between the boiler J-Box and the MCBA or a blown 'F1' fuse in the MCBA. Replace the fuse with the provided 5A fuse.
  • M
    marc70Aug 10, 2025
    How to fix Burnham FREEDOM Boiler displaying U.125?
    • C
      Christopher HigginsAug 10, 2025
      If your Burnham Boiler display continuously reads 'U.125' and the fan is running, it could be caused by a defective AT250 transformer or a blown 'F3' fuse in the MCBA. Replace the fuse with the provided 4A slow-blow fuse.
  • D
    Danielle JohnsonAug 20, 2025
    Why does my Burnham Boiler fire but the display is blank?
    • J
      James ButlerAug 20, 2025
      If the Burnham Boiler fires, but the display panel is blank, it could be due to a loose ribbon cable or a defective display.

Summary

Before Installing

Mounting The Boiler

Wall Mounting

Details on securing the boiler to a framed wall using mounting holes.

Air for Ventilation

Venting

Vent System Design

Explains horizontal, vertical, and twin-pipe vent system configurations for the boiler.

Gas Piping

System Piping

Method 1: Primary;Secondary Piping

Details on installing primary/secondary piping for consistent boiler flow.

Wiring

Start-up and Checkout

FCM Series Lighting and Operating Instructions

Operation

Service and Maintenance

Troubleshooting

Burnham FREEDOM Specifications

General IconGeneral
ModelFREEDOM
Fuel TypeNatural Gas or Propane
EfficiencyUp to 95% AFUE
Water ContentVaries by model
DimensionsVaries by model
WeightVaries by model
AFUEUp to 95%
Boiler TypeCondensing
IgnitionElectronic Ignition
Heat Exchanger MaterialStainless Steel
Vent TypeDirect Vent
WarrantyLimited 5-year warranty on parts