101602-01R9-9/10
Price - $5.00
DNAGNITAREPO,NOITALLATSNI
ROFSNOITCURTSNIECIVRES
ENIPLA
YCNEICIFFEHGIHGNISNEDNOC
TNEVTCERID
RELIOBRETAWTOHDERIF-SAG
As an ENERGY STAR
®
Partner, Burnham by U.S. Boiler Company has determined that the Alpine™ Series meets the
ENERGY STAR
®
guidelines for energy efciency established by the United States Environmental Protection Agency (EPA).
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage,
injury, or loss of life. For assistance or additional information, consult a qualied installer, service agency or the
gas supplier. This boiler requires a special venting system. Read these instructions carefully before installing.
9700609

Other manuals for Burnham ALPINE

Questions and Answers

  • Y
    ypayneAug 19, 2025
    Why is my Burnham Boiler running but the system circulator is not?
    • M
      Maxwell Reeves DDSAug 19, 2025
      If your Burnham Boiler is running but the system or boiler circulator isn't operating, begin by checking the wiring for any loose connections or miswiring. Also, ensure that the parameters are set correctly. If a Domestic Hot Water Heat Request condition is affecting pump operation, allow one hour of “priority protection” before expecting pump operation to resume.
  • M
    Michael BlackwellAug 21, 2025
    What does 'Supply high limit' mean on my Burnham Boiler?
    • N
      Nicole TravisAug 22, 2025
      If the Sage2.1 supply sensor detects temperatures exceeding 210°F in your Burnham Boiler, it triggers a 'Supply high limit' error. This could be due to a defective system pump or a lack of flow in the primary loop. Check these components to ensure they are functioning correctly.
  • J
    John BaxterAug 25, 2025
    Why is my Burnham Boiler not responding to a domestic hot water heat request?
    • G
      Gary HuangAug 25, 2025
      If your Burnham Boiler isn't responding to a domestic hot water heat request, the boiler isn't sensing the demand. Check the wiring for loose connections, miswiring, or a defective indirect water heater aquastat. Ensure all connections are secure and the aquastat is functioning correctly.
  • J
    Jennifer ReedAug 26, 2025
    What does 'DHW high limit' mean on my Burnham Boiler?
    • C
      clarksarahAug 27, 2025
      If the Sage2.1 DHW sensor in your Burnham Boiler detects temperatures exceeding the setpoint, it indicates a 'DHW high limit' issue. This may be caused by a miswired control system. Verify the wiring of your control system to resolve this issue.
  • M
    Michael NelsonAug 28, 2025
    What to do if display panel is blank but fan is running on Burnham Boiler?
    • J
      Jeffrey GrahamAug 28, 2025
      If your Burnham Boiler displays a blank panel but the fan is running, there may be a loose 120VAC connection between the boiler J-Box and the transformer, a loose 24 Vac connection between the transformer and the Sage2.1, or a loose 5 Vdc connection between the display and the Sage2.1. Tighten these connections to resolve the issue.
  • A
    Anna DavisAug 30, 2025
    Why is my Burnham ALPINE Boiler firing but the display panel is blank?
    • J
      Joshua JonesAug 30, 2025
      If your Burnham Boiler is firing, but the display panel is blank, there might be a loose 5 Vdc connection between the display and the Sage2.1, or the display itself could be defective. Try tightening the connection. If the problem persists, consider replacing the display.
  • C
    Christopher KellySep 1, 2025
    What to do if Burnham ALPINE Boiler Safety Limit is Open?
    • H
      heatherbradleySep 1, 2025
      If your Burnham Boiler's safety limit is open, and the boiler safety limit is wired to terminals J6-1, 2, or 3 OPEN, check for loose wiring to the limit device and ensure it is properly connected.
  • V
    Victor GoodSep 3, 2025
    Why is my Burnham ALPINE Boiler not responding to a call for heat and showing “Standby” status?
    • A
      Amber KirkSep 3, 2025
      If your Burnham Boiler is not responding to a call for heat and the “Standby” status is showing, it means the boiler isn't firing. This could be because there is no call for heat, or there is a call for heat, but the temperature is already greater than the setpoint.
  • R
    Rachel MartinezSep 5, 2025
    What to do if home is cold during cold weather days with Burnham ALPINE?
    • V
      Vanessa JosephSep 5, 2025
      If you notice the home is cold during cold weather days using Burnham Boiler, increase the High Boiler Water Temperature parameter 5°F per day to improve heating performance.
  • E
    Eric HunterSep 8, 2025
    What to do if home is cold during mild weather days with Burnham Boiler?
    • S
      Susan JacksonSep 8, 2025
      If you notice the home is cold during mild weather days using Burnham Boiler, increase the Low Boiler Water Temperature parameter 5°F per day to improve heating performance.

Summary

IMPORTANT INFORMATION - READ CAREFULLY

Hazard Definitions

Defines hazard levels like DANGER, WARNING, CAUTION, and NOTICE for safety awareness.

II. Pre-Installation & Boiler Mounting

IV. Venting

VI. Water Piping and Trim

VII. Gas Piping

A. Size gas piping

Guides on determining proper gas pipe size based on capacity and pressure drop.

VIII. Electrical

X. Modular Installation

XI. System Start-up

G. Operating Instructions

Outlines the step-by-step procedure for starting the boiler, including lighting instructions.

XII. Operation

E. Adjusting Parameters

Covers system setup, modulation, pump configuration, and temperature setpoints.

XIV. Troubleshooting

A. Troubleshooting problems where no error code is displayed.

Addresses issues like blank displays or boilers not responding to heat/DHW calls.

Burnham ALPINE Specifications

General IconGeneral
ModelALPINE
Fuel TypeNatural Gas or Propane
EfficiencyUp to 95% AFUE
Heat Exchanger MaterialStainless Steel
Boiler TypeCondensing
WeightVaries by Model
DimensionsVaries by Model