TABLE 7.4a: U.S. BOILER CONCENTRIC 60/100 VENT COMPONENTS (VENT OPTION 1)
PARTNO. DESCRIPTION SIZE
USEDON
VENT
OPTION#
COMMENTS
101005-01
80/125
x60/100mm
REDUCINGELBOW
80/125x
60/100mm
1 INCLUDEDWITHSTANDARDBOILER
101006-01 TERMINALSECTION 60/100mm 1 INCLUDEDWITHSTANDARDBOILER
101007-01 WALLGROMMET 60/100mm 1 INCLUDEDWITHSTANDARDBOILER
101141-01 39”STRAIGHT 60/100mm 1 OPTIONAL-MAYNOTBECUT
101140-01 78"STRAIGHT 60/100mm 1 OPTIONAL-MAYNOTBECUT
101142-01 19-1/2”STRAIGHT 60/100mm 1 OPTIONAL-CANBECUT
101144-01 90DEGREEELBOW 60/100mm 1 OPTIONAL
101143-01 45DEGREEELBOW 60/100mm 1 OPTIONAL
101162-01 39"STRAIGHT 80/125mm 1 OPTIONAL-MAYNOTBECUT(Note #1)
101161-01 78"STRAIGHT 80/125 1 OPTIONAL-MAYNOTBECUT
101167-01 19-1/2"STRAIGHT 80/125 2 OPTIONAL-CANBECUT
Note #1: On60/100mmventsystems,thismayonlybeusedbetweentheboilerandtherst80/125x60/100ReducingElbow(seetext).
PARTNO. DESCRIPTION SIZE
USEDON
VENT
OPTION#
COMMENTS
101490-01 90
DEGREEEL(STANDARD) 80/125mm 3, 6
101542-01 90
DEGREEEL(SWEEP) 80/125mm 3, 6
101491-01 45DEGREEEL 80/125mm 3, 6
101163-01 19-1/2”STRAIGHT 80/125mm 3, 6 CANBECUT
101162-01 39"STRAIGHT 80/125mm 3, 6 CANBECUT
101488-01 39”STRAIGHT 80/125mm 3, 6 MAYNOTBECUT
101161-01 78"STRAIGHT 80/125mm 3, 6 MAYNOTBECUT
101489-01 TELESCOPINGSTRAIGHT 80/125mm 3, 6 ADJUSTABLEFROM12-1/2"TO16-1/2"
101494-01 HORIZONTALTERMINAL 80/125mm 3
101544-01 SNORKELKIT 80/125mm 3 (NOTE#1)
101495-01 VERTICALTERMINAL 80/125mm 6 (NOTE#2)
101496-01 FLATROOFFLASHING 80/125mm 6
101543-01 SLOPEDROOFFLASHING 80/125mm 6 (NOTE#3)
101492-01
SUPPOR
TELBOWWITH
CHIMNEYCHASEBRACKET
80/125mm 6 (NOTE#4)
101498-01 SUPPOR
TBAND 80/125mm 3, 6
TABLE 7.4b: U.S. BOILER CONCENTRIC 80/125 VENT COMPONENTS (VENT OPTIONS 3, 6)
Notes: #1. SnorkelKitincludespartsneededtooffsetterminalonexteriorwallbyupto46".
#2.V
erticalterminalcanbeusedwitheitheroftheroofashingslistedbeneathit.
#3.Slopedroofashingsuitableforroofanglesbetween25and45degrees.