7.1 Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The
intervals given below are considered as starting values which should be shortened or ex-
tended as appropriate. Particularly harsh applications or heavy duty operation, such as
high dust loads in the environment or in the process gas, other contamination or ingress
of process material, can make it necessary to shorten the maintenance intervals signifi-
cantly.
NOTE
The machine must be turned off at the service breaker and secured against wrongful re-
activation during all service work.
Interval Maintenance work
Every 6 months Carry out a visual inspection and clean the machine
from dust and dirt.
Check the electrical connections and the monitoring
devices.
Every 32000 hours Recommend planning a preventive overhaul for every
32000 hours operation.
According to the motor
manual
Check the motor. Lubricate the motor if necessary.
(In accordance with the motor manual).
7.2 Maintenance Inlet Filter
The inlet filter must be cleaned regularly or more often depending on application. The
frequency depends on the application, but the filter must be cleaned at least once every
six months.
The filter must not be washed.
The filter’s dirt level is monitored by the supplied filter gauge that is built into the v-belt
cover or the cabinet front.
Cleaning with compressed air does not ensure a 100% clean wrap filter, it is therefore
recommended to replace it with a new one.
Interval Maintenance work
After 10-20 operating hours Check the inlet filter and clean if necessary. (See
clean or change inlet filter, point 5)
Monthly (or more often de-
pending on application).
Check the inlet filter and clean if necessary. (See
clean or change inlet filter, point 5)
Half - yearly Change the inlet filter (or more often depending on
application). (See clean or change inlet filter, point 5)
Yearly Change the inlet filter (or more often depending on
application). (See clean or change inlet filter, point 5)