EasyManua.ls Logo

BUSCH TYR - Maintenance Oil; Oil Level Inspection

BUSCH TYR
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 | Maintenance
20 / 36 0870231979_WT0100-0730CP_CV_-0001_IM_en
7.4 Maintenance Oil
Bearing temperature
[°C]
See Specific Tech-
nical Data [32]
Interval Maintenance work
After 10-20 operating
hours
Check the oil level,
see Oil Level Inspection [20].
Weekly Check the oil level,
see Oil Level Inspection [20].
After 500 operating
hours
Change for newly operated blower.
≤110 Every 8000 hours Change the oil (min. once a year).
111-130 Every 4000 hours Change the oil (min. every 6 months).
7.5 Oil Level Inspection
Shut down the machine.
When the machine is stopped, wait 1 minute before checking the oil level.
With cabinet
Fill up if necessary, see Oil Filling [13].

Related product manuals