C-COM Satellite Systems Inc.
iNetVu™ 7710 Controller User Manual
31
7.7.4. PL
Displays real-time current drawn and speed settings for the polarization motor, as well as real-
time polarization angle and limits, offset, and PL zero.
Fig. 18: “PL” (Polarization) Display
1 Real-Time Polarization Angle
P (Polarization) Indicates the real time polarization angle of the iNetVu
®
Antenna.
S The letter “S” will appear to indicate the stow Limit has been reached on the polarization
axis
2 Current and Speed Settings
I/S Real-Time current of the polarization motor is to the left of the dash, and speed constant
of the polarization movement is to the right of the dash (i.e. 0.0-2 represents real-time
current of 0.0 and a set speed of 2).
L The letter “L” will appear if there is a ‘left’ movement on the polarization axis.
R The letter “R” will appear if there is a ‘right’ movement on the polarization axis.
See appendix for default speed and current values.
3 - Polarization Offset
This value represents the offset in the polarization angle.
7.7.5. GP
Displays GPS Status and current GPS Heading.
Fig. 19: “GP” GPS Display
P0.0 S I/S:0.0-2 L R
O:0.0
1
2
3
GPS: V V65
LA: 45.4N LG: 75.6W
1
2