4 – Axis Selection and looping option
The first two characters refer to the axis selection (i.e. DD: D).
DD Disable Test for all axes
EL Perform test on the Elevation axis only
AZ Perform test on the Azimuth axis only
PL Perform test on the Polarization axis only
AA Perform tests on all the axes.
The third character refers to the looping intervals between tests (i.e. DD: D or DD: 1).
D Disables looping, test will only be performed once.
1 Infinitely loops with NO_DELAY interval between tests.
2 Infinitely loops with 10-seconds interval between tests.
3 Infinitely loops with 30-seconds interval between tests.
6 Infinitely loops with 1min interval between tests.
9 Infinitely loops with 3min interval between tests.
5 – Test Selection
Initiates the test on the specified axes according to the specified ranges, and speeds. Press up or
down key, first letter will flash then press ENTER, the test routine will start.
7.11.2. DPLY
Fig. 45: Deploy Configuration
1 – Elevation Movement
User-defined elevation angle of deploy
2 – Polarization Movement
User-defined polarization angle of deploy
3 – Azimuth Movement
User-defined azimuth angle of deploy