EasyManua.ls Logo

C-COM Satellite iNetVu 7710 - Page 48

C-COM Satellite iNetVu 7710
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C-COM Satellite Systems Inc.
iNetVu™ 7710 Controller User Manual
48
7.10.4. AZ
The AZ menu allows configuration of compass offset.
1 Compass Offset
A fixed offset could be used to adjust the compass heading. This value would be added to the
calculated compass heading to compensate for any consistent inaccuracy of the compass
reading.
7.10.5. PL
The PL menu allows for the configuration of the polarization axis.
1 - Polarization Offset
By default this polarization-offset value is set to +0°. If there happens to be a requirement for a
polarization offset in the satellite position, the user may manually enter this value in this area.
This area is also updated automatically if the skew adjustment procedure recognizes inaccuracy
in the target polarization angle. Misconfiguring this field will result in undesirable results.
O Indicates a PL offset is allowable and the value is displayed
N Indicates PL is disabled or not applicable
7.10.6. GP
Allows for the Configuration of the GPS parameters and settings
Fig. 36: GPS Configuration
CP_O: +00
1
G :O 45.41N 75.62W
1
2
3
O: +00.0
1