A-7cab Produkttechnik GmbH & Co KG
PIN 7 - XEDST - Print of label has started
The printing of a label is indicated with a 20ms pulse.
XEDST is active if the contact between PIN7 and PIN14 is opened.
PIN 8/12 - GND - Ground (0V)
PIN 9 - RXSTART - Reverse line of the start signal XSTART
PIN 10 - RXFEH - Reverse line of the error signal XFEH
PIN 13 - STA - Start signal is active
The signal STA is necessary to allow the "Print on demand" operating mode.
This signal is active if PIN13 is connected with PIN12 (GND).
In this case the XSTART signal is checked.
PIN 14 - RÜL - Reverse line (for all output signals)
PIN 15 - 24P - Operating voltage +24V, Si T 200mA
The printer provides an operating voltage of 24V at PIN15.
Using that voltage a trigger switch or an optical sensor can be connected to
control the peel-off operation without having an external voltage.
CAUTION !
DO NOT connect any external voltage at PIN 15 !
Appendix A - Operation in Peel-off Mode

Table of Contents

Other manuals for CAB A4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAB A4 and is the answer not in the manual?

CAB A4 Specifications

General IconGeneral
Printer TypeThermal transfer / direct thermal
InterfacesUSB, Ethernet, RS232
Label Thickness Range0.05 mm - 0.25 mm
Memory8 MB Flash
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature+5°C to +40°C
Print Resolution203 dpi
Humidity Range10-85% non-condensing