7956 DC Master Motor fader 8-15
Revision J2005-2 J-Type
;1917 ,VROD WH
When this button is pressed, the fader is disconnected from the computer system. It
cannot send commands to the computer and it cannot receive commands to the
computer. It will still drive the DC busses and affect the channels assigned to it.
All faders can be put in isolate mode by pressing the ALL FADER ISOLATE “SET
SWITCH on the master fader control panel below the CCM module. Similarly, all fad-
ers can be taken out of isolate mode by pressing the ALL FADER ISOLATE “CLEAR
switch on the same panel.
;1918 :ULWH
As soon as the fader knob is touched, this LED comes on and dynamic data is sent
to the PC. The fader will no longer respond to movements sent by the PC.
;1919 5HDG\
This LED indicates that fader data can be sent to the PC. However no data will be
sent until the Write mode is invoked by touching the fader knob. The fader will in this
state respond to movement commands from the PC.
;191: 6DIH
This LED indicates ‘safe’ mode. No dynamic data will be sent to the PC. The fader
will respond to movement commands from the PC.
;191; )DGHU
A standard 100 mm fader controlling all channel VCA and motor faders selected to it.
The fader position can be saved and recalled as part of a normal cue or in a dynamic
cue.
;191< )DGHU#2SHQ
This LED illuminates as soon as the fader moves away from the infinity, unless the
MUTE is set ON.