EasyManua.ls Logo

CalderaSpas Utopia Series - SAFETY INSTRUCTIONS; Avoiding the Risk to Children; Avoiding the Risk of Electrocution

CalderaSpas Utopia Series
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
AVOIDING THE RISK TO CHILDREN
Danger:
• RISK OF CHILD DROWNING. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot
use a spa unless they are supervised at all times.
Warning:
• Toreducetheriskofinjury,donotpermitchildrentousethisspaunlesstheyarecloselysupervisedatalltimes.
• Toreducetheriskofinjury,lowerwatertemperaturesarerecommendedforyoungchildren.Childrenareespeciallysensitivetohotwater.
DO:
• Makesureyoualwayslockthechildresistantlocksafterusingthespaforyourchildren’ssafety.EveryCaldera
®
spa is equipped with a locking cover that meets
the ASTM F1346-91 Standard for Safety Covers.
• Testthewatertemperaturewithyourhandbeforeallowingchildrentoenterthespatobesurethatit’scomfortable.Childrenareespeciallysensitivetohotwater.
• Remindchildrenthatwetsurfacescanbeveryslippery.Makesurethatchildrenarecarefulwhenentering,orexitingthespa.
DOn’T:
• Allowchildrentoclimbontothespacover.
• Allowchildrentohaveunsupervisedaccesstothespa.
AVOIDING THE RISK OF ELECTROCUTION
risk Of elecTrOcuTiOn
• Connectonlytoagroundedsource.
• Donotburythepowercord.Aburiedpowercordmayresultindeath,orseriouspersonalinjuryduetoelectrocutionifdirectburial-typecableisnotused,orif
improper digging occurs.
• Agroundterminal(pressurewireconnector)isprovidedonthecontrolboxinsidetheunittopermitconnectionofaminimumNo.10AWGsolidcopperbonding
conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical equipment, or conduit within five feet (1.5 m) of the unit
as needed to comply with local requirements.
• Donotoperatethemainaudiocontrolswhileinsidethespa(ifthespaisequippedwithanaudiocomponent).
• Donotconnectanyauxiliarycomponents(forexample,additionalcablespeakers,headphones,orotheraudiocomponents)totheaudiosystemunless
approved by Watkins Manufacturing Corporation.
• Donotself-serviceaudiocomponentsbyopeningorremovingthecoverasthismayexposeyoutodangerousvoltageorotherriskofinjury.Onlyqualified
service personnel should service your spa and its components.
• DonotattachanexternalantennatoaspaaudiosystemunlessitisinstalledbyalicensedelectricianinaccordancewithArticle810oftheNationalElectric
Code, ANSI/NFPA 70.
Warning:
• Toreducetheriskofelectricalshock,replaceadamagedcordimmediately.Failuretodosomayresultindeathorseriouspersonalinjuryduetoelectrocution.
• YourspaisprovidedwithaGroundFaultCircuitInterrupterforuserandequipmentprotection.Toensureproperoperationofthisimportantsafetydevice,test
according to the following instructions per electrical configuration.
230 volt, permanently installed models:
• Agroundterminalisprovidedontheterminalblocklocatedinsidethecontrolbox.Toreducetheriskofelectricshock,connectthisterminaltothegrounding
terminal of your electrical service or supply panel with a continuous green, insulated copper wire. The wire must be equivalent in size to the circuit conductors
supplying the equipment. In addition, a bonding terminal (pressure wire connector) is provided on the outside of the control box for bonding to local ground
points. To reduce the risk of electric shock, this connector should be bonded with a No. 10 AWG solid copper wire to any metal ladders, water pipes, or other
metal within 5 feet (1.5 m) of the spa to comply with local requirements. The means of disconnection must be readily accessible, but must be installed at least 5
feet (1.5 m) from the spa.
• Yourspaisprovidedwithasuitablyratedcircuitbreakertoopenallungroundedsupplyconductors.
• Yourspausesgroundfaultcircuitinterruptersintheelectricalsubpanel.Beforeeachuseofthespaandwiththeunitoperating,pushtheTESTbuttononeach
breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by switching it completely off, and then completely on.
The switch should then stay on. If either interrupter does not perform in this manner, it is an indication of an electrical malfunction and the possibility of an electric
shock. Disconnect the power until the problem has been corrected.
SAFETY INSTRUCTIONS

Table of Contents

Other manuals for CalderaSpas Utopia Series

Related product manuals