VALEUR DISJONCTEUR
CIRCUIT
ELECTRIQUE
2.5A
VENTILATEUR 1 ET 2
COMPRESSEUR 1 ET 2
23.8A
1.7A
VOYANT
ALIMENTATION
L3 L2 L1
MONITEUR DE
PHASES
DISJONCTEUR
CIRCUIT ELECTRIQUE
6 (N/F)
5
4 (N/F)
3
2 (N/F)
1
TEMPORISATION 1
(12 HEURES)
VOYANT
DEGIVRAGE
THERMOSTAT
DE GIVRAGE
CIRCUIT 1
THERMOSTAT
DE GIVRAGE
CIRCUIT 2
CIRCUIT 1
VOYANT
DEFAUT
CIRCUIT 2
VOYANT DEFAUT
CONTACT DEFAUT
COMPRESSUER 1
PRESSOSTAT BP
(SE COUPE A H EN
BASSE PRESSION)
PRESSOSTAT HP
CIRCUIT 1 FRIGORIFIQUE
(SE COUPE A L EN
HAUTE PRESSION)
PRESSOSTAT BP
(SE COUPE A H EN
BASSE PRESSION)
CONTACT DEFAUT
COMPRESSUER 2
PRESSOSTAT HP
CIRCUIT 2 FRIGORIFIQUE
(SE COUPE A L EN
HAUTE PRESSION)
COMP 1
RECHAUFFEUR COMP 1
ELECTROVANNE (ARRET
LIGNE LIQUIDE)
CIRCUIT 1
COMP 2
A1
A2
CONTACTEUR
VENTILATEUR 1
6 (N/O) 5
34 (N/O)
12 (N/O)
CONTACTEUR
COMP 2
22 (N/F)
64 (N/O)
63 (AUX)
VENTILATEUR 1
VENTILATEUR 2
RECHAUFFEUR COMP 2
6 (N/F) 5
4 (N/F) 3
2 (N/F) 1
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
DISJONCTEUR VENTILATEUR 2
DISJONCTEUR
COMPRESSEUR 1
DISJONCTEUR
COMPRESSEUR 2
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CIRCUIT 2
NEUTRE
(COM) 1
3 (N/F) [VEILLE (0)]
[MARCHE (I)]
(N/O) 2
COMMUTATEUR
VEILLE
CONTACT 4 ET 6 EN
BASSE TEMPERATURE
SONDE
THERMOSTAT
BORNES
D'ALIMENTATION
HORLOGE
TEMPORISATION
2 (6 MINS)
TEMPORISATION 3
(7 MINS)
VOYANT DEBIT D'EAU
COMPRESSEUR 2
MCB AUX
COMPRESSEUR 1
MCB AUX
VOYANT
DEFAUT
DEMARRAGE AMORTI
AVEC DISJONCTEUR
THERMIQUE
SI INSTALLE
BORNES
D'ASSERVISSEMENT
CONTACT DEBIT
D'EAU (INTERNE)
CONTACT DEFAUT
VENTILATEUR 1
CONTACT DEFAUT
VENTILATEUR 2
DEMARREUR OU
CONTACTEUR DE
DEBIT (EXTERNE)
PROTECTION THERMIQUE
VENTILATEUR 1
PROTECTION MOTEUR
COMPRESSOR 1
PROTECTION THERMIQUE
VENTILATEUR 2
PROTECTION MOTEUR
COMPRESSOR 2
OUT 1
14 (N/O)
95
(N/F) 96
95
(N/F) 96
TK
TK
(N/F) TK
(N/F) TK
(N/F)
(N/F)
6 (COM)
1 (L)(N) 2
(N/O) 4
(N/F) 5
L1
L2
L3
11 (COM)
12 (N/F)
9 (L)(N) 8
AB
4 (N/O)
1 (N/F)
6 (N/O)
3 (N/F)
10
11
(COM) 7
(COM) 9
RELAIS (R2)
(COM)
C
(N/O) H
L
(N/C)
AB
(N/F) 1
(N/O) 4
7
(COM)
RELAIS (R3)
B
B
1 (N/F)
4 (N/O)
(COM) 7
3 (N/F)
6 (N/O)
(COM) 9
RELAIS (R4)
7 (COM)
(N/O) 4
(N/F) 1
(COM) C
(N/O) H
L (N/F)
A
A
RELAIS (R5)
1 (N/F)
(COM) 7 4 (N/O)
53
(N/F) 54
15 (COM)
18 (N/O)
16 (N/F)
A1A2
A1A2
2
A2 A1 (COM) 9
53
54 (N/F)
3 (N/F)
6 (N/O)
15 (COM)
16 (N/F)
18 (N/O)
A1A2
95
(N/C) 96
(COM) C
(N/O) L H (N/C)
(COM)
C
(N/O) H
L (N/C)
AB
RELAIS (R1)
15 (COM)
18 (N/O)
16 (N/F)
A1A2
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)(N/C) 22
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)
10
11
7
6
6 (N/F)
4 (N/F)
2 (N/F)
5
3
1
95
96 (N/F)
C (COM)
L (N/O)
C (COM)
H (N/O)
1
H (N/F)
L (N/F)
U1
V1
W1
U1
V1
W1
(N/F)
(N/F) 1
(N/O) 4 7 (COM)
AB
RELAIS (R6)
63 (AUX)(N/O) 64
WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT MAXIMUM RATE
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY
NOTE
DISJONCTEUR VENTILATEUR 1
CONTACTEUR
VENTILATEUR 2
6 (N/O) 5
34 (N/O)
12 (N/O)
A1
A2
CONTACTEUR
COMP 1
COMPRESSEUR 1
MCB AUX
COMPRESSEUR 2
MCB AUX
PROPAC 90BM TRIPHASEE (400V ~ 3 N 50Hz)
(SE COUPE A H EN
BASSE TEMPERATURE)
(SE COUPE A H EN
BASSE TEMPERATURE)
19
SD566252 ISSUE 51