L3 L2 L1
CONTACT DEBIT
D'EAU
(INTERNE)
BORNES
D'ALIMENTATION
HORLOGE
DISJONCTEUR
CIRCUIT
ELECTRIQUE
MONITEUR DE
PHASES
CONTACT DEFAUT
COMPRESSEUR 2
PRESSOSTAT BP
CIRCUIT FRIGORIFIQUE 2
(SE COUPE A H EN
BASSE PRESSION)
PRESSOSTAT HP
(SE COUPE A L EN
HAUTE PRESSION)
TEMPORISATION (1)
12 HEURES
TEMPORISATION
(2)
6 MINS
TEMPORISATION
(3)
7 MINS
3 (N/C)
VEILLE (O)
MARCHE (I)
(N/O) 2
COMMUTATEUR
VEILLE
NEUTRE
VOYANT
DEFAUT
VOYANT ALIMENTATION
VOYANT
DEGIVRAGE
CIRCUIT 1
VOYANT
DEFAUT
* 1
CIRCUIT
2
VOYANT
DEFAUT
* 2
CONTACT
AUXILLAIRE
(DISJONCTEUR
COMPRESSEUR 1
CONTACT
AUXILLAIRE
(DISJONCTEUR)
COMPRESSEUR 2
VOYANT DEBIT D'EAU
THERMOSTAT
DE
DEGIVRAGE
CIRCUIT 1
(SE COUPE A 'H'
EN BASSE
TEMPERATURE)
THERMOSTAT
DE
DEGIVRAGE
CIRCUIT 2
(SE COUPE A
'H' EN BASSE
TEMPERATURE
THERMOSTAT
CONTACT 6 ET 4 EN
BASSE TEMPERATURE
COMP
1
COMP
2
CONTACTEUR
COMP 2
CONTACTEUR
COMP 1
CONTACTEUR
VENTILATEUR 1
VENTILATEUR
1
DISJONCTEUR VENTILATEUR 1
VENTILATEUR
2
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CURCUIT 1
RECHAUFFEUR
COMPRESSEUR 2
RECHAUFFEUR
COMPRESSEUR 1
DISJONCTEUR
VENTILATEUR 2
DISJONCTEUR
COMPRESSEUR 1
DISJONCTEUR
COMPRESSEUR 2
CONTACTEUR
VENTILATEUR 2
CONTACT DEFAUT
COMPRESSEUR 1
PRESSOSTAT BP
CIRCUIT FRIGORIFIQUE 1
(SE COUPE A 'H'
EN BASSE PRESSION)
PRESSOSTAT HP
(SE COUPE A 'L'
EN HAUTE PRESSION)
BORNES
D'ASSERVISSEMENT
DEMARRAGE
AMORTI AVEC
DISJONCTEUR
THERMIQUE
SI INSTALLE
DEMARREUR OU
CONTACTEUR DE
DEBIT (EXTERNE)
CONTACT DEFAUT
VENTILATEUR 2
CONTACT DEFAUT
VENTILATEUR 1
PROTECTION THERMIQUE
VENTILATEUR 2
PROTECTION THERMIQUE
VENTILATEUR 1
CIRCUIT
ELECTRIQUE
2.5A
VALEUR DISJONCTEUR
2.6A
VENTILATEUR 1&2COMPRESSEUR 1&2
30.7A
OUT 1
14 (N/O)
96
(N/F) 95
96
(N/F) 95
TK
TK
(N/F) TK
(N/F) TK
(COM) 1
6 (COM)
1 (L)(N) 2
(N/O) 4
(N/F) 5
5
1
3
2 (N/F)
4 (N/F)
6 (N/F)
L1
L2
L3
11 (COM)
12 (N/F)
9 (L)(N) 8
AB
4 (N/O)
1 (N/F)
6 (N/O)
3 (N/F)
SONDE
10
11
(COM) 7
(COM) 9
RELAIS (R2)
(COM) C
(N/O) H
L (N/F)
AB
(N/F) 1
(N/O) 4 7 (COM)
RELAIS (R3)
B
B
1 (N/F)
4 (N/O)
(COM) 7
3 (N/F)
6 (N/O)
(COM) 9
RELAIS (R4)
7 (COM)
(N/O) 4
(N/F) 1
(COM) C
(N/O) H
L (N/F)
A
A
RELAIS (R5)
1 (N/F)
(COM) 7 4 (N/O)
33
(N/F) 34
15 (COM)
18 (N/O)
16 (N/F)
A2A1
COMPRESSEUR 1
CONTACTEUR
A1A2
A1 A2
COMPRESSEUR 2
CONTACTEUR
(COM) 9
33
34 (N/F)
3 (N/F)
6 (N/O)
15 (COM)
16 (N/F)
18 (N/O)
A1A2
44
(N/F) 43
(COM) C
(N/O) L
H (N/F)
(COM) C
(N/O) H
L (N/F)
AB
RELAIS (R1)
15 (COM)
18 (N/O)
16 (N/F)
A1A2
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
TRIP / OFF = BREAK CONTACT
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
A2A1
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
A2A1
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)(N/F) 22
1
3
5
(N/F) 2
(N/F) 4
(N/F) 6
1
3
5
(N/O) 2
(N/O) 4
(N/O) 6
21 (AUX)(N/F) 22
10
11
7
6
44
43 (N/F)
C (COM)
L (N/O)
C (COM)
H (N/O)
H (N/F)
L (N/F)
L1
L2
L3
L1
L2
L3
13 (AUX)(N/O) 14
(N/F)
(N/F) 1
(N/O) 4 7 (COM)
AB
RELAIS (R6)
W1
W1
V1
V1
U1
U1
13 (AUX)(N/O) 14
WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT MAXIMUM RATE
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED
WHERE CONTACTS ARE MARKED (N/O) OR (N/F) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY
NOTE
ELECTROVANNE
(ARRET LIGNE LIQUIDE)
CURCUIT 2
PROPAC 140BM TRIPHASEE (400V ~ 3 N 50Hz)
20
SD566252 ISSUE 51
SYSTEME PRO-PAC MANUEL D’INSTALLATION