EasyManua.ls Logo

Calpeda e-idos E-MXPM - User Manual

Calpeda e-idos E-MXPM
96 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Sistema di pressurizzazione con controllo integrato
Pressure boosting system with integrated control
Wasserversorgungsanlage mit Integrierter Drucksteuerung
Système de surpression avec contrôle intégré
Sistema de presurización con control integrado
Trycksystem med integrerad styrning
Drukverhogingsinstallatie met geïntegreerde besturing
Σύστημα συμπίεσης με ενσωματωμένο έλεγχο
Система повышения давления со встроенным управлением
集成控制的增压系统

E-MXPM, E-MXAM, E-NGXM
ISTRUZIONI ORIGINALI PER L’USO Pagina 2 Italiano
OPERATING INSTRUCTIONS Page 10 English
BETRIEBSANLEITUNG Seite 18 Deutsch
INSTRUCTIONS POUR L’UTILISATION Page 26 Français
INSTRUCCIONES DE USO Página 34 Español
DRIFT/INSTALLATIONSANVISNINGAR Sidan 42 Svenska
BEDIENINGSVOORSCHRIFT Pagina 50 Nederlands
ΟΔΗΓΙΕΣ ΧΕΙΡΙΣΜΟΥ Σελίδα 58 Ελληνικά
àÌÒÚÛ͈ËË ÔÓ ˝ÍÒÔÎÛ‡Ú‡ˆËË ëÚ. 66 êÛÒÒÍËÈ
安装使用手册 页码 74 中文
  81 
Reg. U.S. Pat. and TM. Off.
E-MXAM E-MXPM E-NGXM Rev6.indd 1E-MXAM E-MXPM E-NGXM Rev6.indd 1 02/02/22 14:3502/02/22 14:35

Table of Contents

Questions and Answers

  • S
    Stacy CunninghamAug 14, 2025
    Why won't my Calpeda Water Pump motor start?
    • B
      brownmollyAug 14, 2025
      If the Calpeda Water Pump motor doesn't start, first ensure the mains frequency and voltage match the electrical characteristics on the indicator plate. If the power supply is correct, check for and remove any shaft blockages. If these steps don't resolve the issue, the engine may need repair or replacement.
  • C
    Christian JordanAug 17, 2025
    What to do if Calpeda Water Pump runs but no water comes out?
    • D
      Derek RiveraAug 17, 2025
      If your Calpeda Water Pump is running but not pumping water, examine the suction tube connections, drain plugs, pump filling points, and suction pipe gaskets for air leaks and seal any loose connections. Also, inspect the foot valve for blockages and ensure the suction pipe is fully submerged in the liquid. Clean or replace the bottom valve and use a suitable suction pipe. Check the suction filter and clean or replace it if blocked. Finally, verify the integrated non-return valve is functioning correctly.
  • M
    Michael GibsonAug 21, 2025
    How to improve Calpeda Water Pump flow?
    • W
      Wendy WalshAug 21, 2025
      If you're experiencing insufficient flow with your Calpeda Water Pump, start by checking if the pipes and accessories are adequately sized to prevent excessive head loss; use suitable pipes and accessories for your application. Next, inspect the rotor for deposits or solid bodies and clean it; install a suction filter to prevent future blockages. If the rotor is deteriorated, replace it. Ensure that the viscosity of the liquid isn't too high. Reduce the suction head if it's excessive. Shorten the suction pipe or use a wider diameter pipe.
  • G
    gateschristopherAug 25, 2025
    What to do if my Calpeda Water Pump does not stop running?
    • A
      Amanda CaseyAug 25, 2025
      If your Calpeda Water Pump won't stop, check the integrated check valve for any blockages or solid parts and remove them. Also, review the UP01 parameter for the stop pressure and reduce it if it's too high.
  • D
    Debra RoseAug 27, 2025
    Why is my Calpeda Water Pump making noise and vibrating?
    • D
      Derek WalkerAug 27, 2025
      If your Calpeda Water Pump is producing excessive noise and vibrations, first check the rotor for obstructions. If there are no obstructions, inspect the bearings for wear and replace them if necessary. Ensure the pump and pipes are firmly attached. If the flow is too strong for the delivery pipe, use larger diameter pipes or reduce the pump flow. If the pump is cavitating, reduce the flow and/or use pipes with a larger internal diameter.
  • S
    Sarah HamiltonAug 30, 2025
    How to unblock a Calpeda Water Pump?
    • E
      Eric HarrisAug 31, 2025
      To unblock a Calpeda Water Pump, if rust has formed due to inactivity, use a screwdriver to turn the notch on the back of the shaft after turning off the electricity. If solid bodies are present in the rotor, dismantle the pump casing and remove them. If the bearings are seized, replace them.
  • J
    Justin WhiteSep 3, 2025
    Why does my Calpeda Water Pump work intermittently?
    • J
      John Wilson MDSep 3, 2025
      If your Calpeda Water Pump is working intermittently, check the built-in check valve for proper function and remove any solid parts. Also, check the tank pressure.
  • I
    iriveraSep 6, 2025
    Why is my Calpeda Water Pump leaking from the mechanical seal?
    • T
      Theresa MatthewsSep 6, 2025
      If there's leakage from the mechanical seal of your Calpeda Water Pump, and the seal has functioned dry, has been scored by abrasive parts, or is unsuitable for the application, replace it. Ensure the pump casing and suction pipe are full of liquid and air has been expelled. Install a suction filter and use a seal suited to the liquid being pumped. If there's a slight initial drip, wait for the seal to adjust.
  • W
    William ThompsonSep 10, 2025
    What causes excessive starts per hour in a Calpeda Water Pump?
    • S
      sophia97Sep 10, 2025
      If your Calpeda Water Pump is starting too frequently, check the tank pressure and consider installing a higher capacity tank.

Summary

General Information

Symbols

Explains symbols used in the manual for safe operation.

Technical Description

Intended Use

Defines the acceptable liquids and temperature range for the pump.

Improper Use

Prohibits misuse and states manufacturer liability for accidents.

Technical Features

Technical Data

Lists technical specifications like speed, voltage, frequency, and pressure.

Pushbuttons Functions

Describes the functions of each pushbutton on the user interface.

Safety

General Provisions

Emphasizes reading safety, following local regulations, and avoiding improper use.

Individual Protection Devices

Recommends using individual protection devices during installation, starting, and maintenance.

Transportation and Handling

Handling

Provides guidelines for careful handling, avoiding impacts, and lifting heavy packages.

Installation

Ambient Requirements and Installation Site

Details customer responsibilities for site preparation and environmental requirements.

Installation

Refers to installation examples and general placement advice.

Programming Guide

Parameters

Lists the available and programmable parameters.

UP - User Settings

Details user-configurable settings like stop/restart pressure and operating mode.

AP - Advanced Settings

Covers advanced settings accessible with a password, including factory reset.

Startup and Operation

Parameters to be set at the Start-up

States that parameters are pre-set but advises checking system stop with closed taps.

First Starting

Provides critical instructions for initial pump filling and starting to avoid dry running.

Self-priming (Only for E-MXA, E-NGX)

Details the self-priming process and conditions for specific pump models.

Abnormal Operation

Warns against running the pump dry or with a closed port and provides temperature guidance.

Maintenance

Routine Maintenance

Stresses disconnecting power before maintenance and provides advice on handling corrosive water.

Disposal

Spare Parts

Spare-parts Request

Outlines how to request spare parts, including required information.

Designation of Parts

Lists parts with their designation numbers, relevant for ordering.

Alarms

Troubleshooting

Installation Examples

Drawing for Dismantling and Assembly

Minimum Conductor Cross-Sectional Area

Calpeda e-idos E-MXPM Specifications

General IconGeneral
Motor ProtectionIP 44
Insulation ClassF
Applicationsirrigation, pressure boosting
Materialscast iron
Power1.1 kW
Frequency50 Hz
Inlet/Outlet Size1"
Materialcast iron

Related product manuals