Questions and Answers

  • B
    bhannaAug 16, 2025
    What to do if the Calpeda Unimat-E is not starting?
    • X
      xsolomonAug 16, 2025
      If the Calpeda Water Pump isn't starting, first, make sure the green light on the front of the unit is on, and check the fuse. Then, push the float valve to check if water is filling the tank, and check the water level and supply. Verify the unit is working correctly and check the set system pressure. Use the pump test function to force the pumps to run and clear any errors. If the system set pressure is higher than the pump's capability, reduce the set pressure. Make sure you have the right unit for the system pressure needed. Remove pressure from the unit outlet and confirm the displayed pressure is 0 bar. If the sensor signal is outside parameters, an error will show, in which case the sensor should be replaced.
  • V
    Veronica HarrisAug 19, 2025
    Why is the high pressure alarm triggered on my Calpeda Water Pump?
    • L
      Luis ButlerAug 19, 2025
      The high pressure alarm on your Calpeda Water Pump may be triggered because the system pressure is too high or there's a fault with the pressure sensor. To resolve this, check the system operation. You can increase the high pressure alarm set pressure. Also, remove pressure from the unit outlet and verify the displayed pressure is 0 bar. If the sensor signal is outside of normal, an error will be displayed.
  • L
    Lynn GrimesAug 22, 2025
    What to do if Calpeda Unimat-E Water Pump runs longer than set time?
    • P
      pacemelissaAug 22, 2025
      If your Calpeda Water Pump runs longer than the set time, activating the pump run time alarm, it could be due to the pump filling the system or a leak in the system. You can activate the system fill option to suppress the alarm for 24 hours. Check the system for leakage and monitor using the system fill volume log, resetting if needed. You might also need to increase the pump run time limit.
  • D
    Dr. Jasmine LewisAug 26, 2025
    How to fix a Calpeda Unimat-E when it won't stop?
    • C
      Colton ThompsonAug 26, 2025
      If your Calpeda Water Pump won't stop, it could be because the system pressure is set too high or there is a pressure sensor fault. Reduce the set pressure if it exceeds the pump's capability and ensure you have the correct unit for the system pressure required. Remove pressure from the unit outlet to check if the displayed pressure is 0 bar. If the sensor signal is outside parameters, an error will be displayed.
  • D
    Deanna BishopAug 28, 2025
    What to do if my Calpeda Water Pump activity high alarm activated?
    • M
      Mary BrownAug 28, 2025
      If the Activity High alarm is activated on your Calpeda Water Pump, and the pump is starting more than the set value, it could be due to the pump filling the system, a leak in the system, or the Activity High alarm number being too low. To address this, activate the system fill option to suppress the alarm for 24 hours. Check the system for leakage, monitor it using the system fill volume log, and reset if needed. Also, consider increasing the Activity High alarm value.
  • C
    colonericAug 31, 2025
    Why is the low pressure alarm triggered on my Calpeda Water Pump?
    • D
      Dawn DixonAug 31, 2025
      The low pressure alarm on your Calpeda Water Pump can be triggered by a leak in the system, the low pressure alarm being set too high, or a pressure sensor fault. Check the system for leaks and review pump activity in the logs. Also, check for a leaking pressure relief valve. Reduce the low pressure alarm pressure and check the system pressure range during normal operation. Remove pressure from the unit outlet and verify the displayed pressure is 0 bar. If the sensor signal is outside of normal, an error will be displayed.
  • Y
    ysmithSep 3, 2025
    What to do for sensor failure error in Calpeda Unimat-E Water Pump?
    • D
      Debra BaldwinSep 3, 2025
      To address a sensor failure error in your Calpeda Water Pump, which occurs when the pressure sensor is outside specification, remove pressure from the unit outlet and verify the displayed pressure is 0 bar. An error will be displayed if the sensor signal is outside parameters.
  • J
    Jennifer AustinSep 6, 2025
    How to troubleshoot Calpeda Unimat-E when there is no power?
    • L
      laura32Sep 6, 2025
      If there is no power to your Calpeda Water Pump, and the internal re-settable fuse has tripped, check the power supply and the fuse. Remove mains power from the unit for 20 seconds, then re-apply the power.
  • H
    Heather JohnsonSep 9, 2025
    What to do if there is low water error in Calpeda Unimat-E?
    • W
      William RiosSep 9, 2025
      If you're getting a low water error with your Calpeda Water Pump, it could be due to a loss of water supply to the unit or the water level being set too low. Depress the float valve to verify water is filling the tank, and check the water level and supply. Adjust the water level by turning the float, making sure the upper level probe is in contact with water when the fill valve is turned off. Check the water level before leaving the unit unattended.
  • F
    Faith DavisSep 12, 2025
    Why is water overflowing from the warning pipe of my Calpeda Water Pump?
    • B
      Brenda PetersonSep 12, 2025
      If water is overflowing from the warning pipe or weir of your Calpeda Water Pump, it's likely due to the water level being too high or the pump NRV (Non-Return Valve) leaking. Check the function of the fill valve, and replace or adjust it if needed. Isolate the unit from the system and mains water, then replace the non-return valve and holder.