Technical data
MODELS A3000 A3000A A3010 A3006 A3100 A3106
Motor power supply (V)
230 AC
50/60 Hz
230 AC
50/60 Hz
110 AC
50/60 Hz
230 AC
50/60 Hz
230 AC
50/60 Hz
230 AC
50/60 Hz
Power (W) 260 260 260 260 260 260
Capacitor (μF) 10 10 50 10 10 10
Current draw (mA) 1,2 1,2 2.6 1,2 1,2 1,2
Operating temperature (°C) -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55
Thrust (N) 400 ÷ 4000 400 ÷ 4000 400 ÷ 3000 400 ÷ 4000 400 ÷ 4000 400 ÷ 4000
Opening time at 90° (s) 19 ÷ 25 19 ÷ 25 19 ÷ 25 28 ÷ 35 19 ÷ 25 28 ÷ 35
Sound pressure level (dB A) ≤70 ≤70 ≤70 ≤70 ≤70 ≤70
Protection rating (IP) 44 44 44 44 44 44
Insulation class IIIIII
Reduction ratio (i) 36 36 36 36 36 36
Weight (kg) 10 10 10 10 10 10
Storage temperature (°C) -20 ÷ +70 -20 ÷ +70 -20 ÷ +70 -20 ÷ +70 -20 ÷ +70 -20 ÷ +70
Average life (hours) 120000 120000 120000 120000 120000 120000
MODELS A5000 A5000A A5006 A5010 A5100 A5106
Motor power supply (V)
230 AC
50/60 Hz
230 AC
50/60 Hz
230 AC
50/60 Hz
120 AC
50/60 Hz
230 AC
50/60 Hz
230 AC
50/60 Hz
Power (W) 260 260 260 260 260 260
Capacitor (μF) 10 10 10 50 10 10
Current draw (mA) 1,2 1,2 1,2 2.6 1,2 1,2
Operating temperature (°C) -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55
Thrust (N) 400 ÷ 4000 400 ÷ 4000 400 ÷ 4000 400 ÷ 4000 400 ÷ 4000 400 ÷ 4000
Opening time at 90° (s) 30 ÷ 40 30 ÷ 40 40 ÷ 50 30 ÷ 40 30 ÷ 40 40 ÷ 50
Sound pressure level (dB A) ≤70 ≤70 ≤70 ≤70 ≤70 ≤70
Protection rating (IP) 44 44 44 44 44 44
Insulation class IIIIII
Reduction ratio (i) 36 36 36 36 36 36
Weight (kg) 11 11 11 11 11 11
Storage temperature (°C) -20 ÷ +70 -20 ÷ +70 -20 ÷ +70 -20 ÷ +70 -20 ÷ +70 -20 ÷ +70
Average life (hours) 120000 120000 120000 120000 120000 120000
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a
very high or very low temperature.
(**) The average product life is a purely indicative estimate. It applies to compliant usage, installation and
maintenance conditions. It is also infl uenced by other factors, such as climatic and environmental conditions.