CAME BPT THANGRAM - Connectors and Switches; DIP-1 Video Line Setup; DIP-2-3 Data Line Setup; Signals

CAME BPT THANGRAM
48 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VA/08
VA/08
VA/08
VA/08
L
L
DVC/08
DVC/08 ME
DC/08
DC/08 ME
A
Page 3 - Manual FB00864-EN - ver. 1 - 08/2017 - © CAME S.p.A. - The contents of this manual are subject to change at any time without prior notice.
Connectors
6 CN2: Connector for the keyboard or RFID access control module.
7 CN4: Additional push button panel connector.
8 MINI USB: Programming connector.
A Switch SW2 9
Dip-1 Video line setup
OFF
L<150 m
ON
150<L<250 m
Dip-2-3 Data line setup
OFF
OFF
L<500 m
ON
ON
500<L<1000 m
Signals J
Red - Call in progress
Green - Door open
Yellow - Conversation in progress
Blue - System busy
Technical data
Type DC/08-DVC/08 - DC/08 ME-DVC/08 ME
Power supply (VDC)
14-18
Absorption (mA)
200
Consumption in stand-by mode (mA)
90
Storage temperature (°C)
-25 ÷ + 70
Operating temperature (°C)
-15 ÷ + 50
IP Degree
54
Camera
Standard video
PAL/NTSC
Resolution (pixel)
680x512
Minimum lighting (LUX)
1