- 05/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
With two coupled gearmotors, you can command only the opening (by button and/or radio control): the gate will close only in automatic
closing mode.
• Coordinate the direction of travel of the two gearmotors 󱤨 and 󱤩, by modifying the motor's rotation 󱤩 (invert the cables on
terminals FA-FC and U-V).
• Make the electrical connections only on
the motor's control board 󱤨.
8 Connecting two coupled gearmotors having a single control
• Whereas, the adjustments and features, must be made on both boards.
• Connect the two boards together, as illustrated.
• Set DIP 2 and 1 to ON on both boards.
• Fit the AF board only into the gearmotor's
board 󱤨.
The transmitter button for opening must be