POWER SUPPLY
230 V AC - 50/60 Hz
Output to power 24 V AC accessories (normally) - max. 40 W.
If the power is out, you can power up the 24 V DC accessories by
using buffer batteries.
Output to notify the state of the barrier (Contact rated for: 24 V AC - 3 W max.).
It flags the state of the barrier, see function F10.
Output for connecting the luminous cord (Contact rated for: 24 V AC - 32 W
max.).
It flags the state of the barrier, with intermittent lights, see function F15.
Additional light connection output (Contact rated for: 24 V AC - 25 W max):
- flashing light, that flashes when the barrier is opening and closing.
- cycle or courtesy light, which is a freely positionable outdoor light for
enhanced lighting in the driveway.
Cycle, stays on from the moment in which the barrier starts opening until it
closes completely (including the automatic closing time).
Courtesy, stays on a settable time of between 60 and 1180 seconds, see
function F18.