TRAVEL CALIBRATION
⚠
During the calibration, all safety devices will be disabled except for the PARTIAL STOP one.
Select A3 and press ENTER to confirm.
Select 1 and press ENTER to confirm the travel calibration operation.
The operator will perform a closing maneuver until the limit-switch point ...
then, the barrier will perform an opening maneuver until the endstop point.
SETTING UP
Once the connections are all set, have skilled, qualified staff commission the barrier into service.
Before continuing, make sure that the way is clear from any obstruction.
Power up and begin configuring the system. Important! Start programming by first doing the following functions:
- type of boom (see function A1);
- motor test (see paragraph called MOTOR TEST);
- total stop (see function F1);
- calibrating travel (see paragraph called CALIBRATING TRAVEL).
MOTOR TEST
Select A2. Press ENTER to confirm
Select 1 to activate the test. Press ENTER to confirm ...
... the following characters will appear (----), while standing by for a command.
Keep pressed the button with the arrow < and check whether the operator performs an opening maneuver.
If the operator performs a closing maneuver, invert the motor's phases (M with N).
When the programming is done, check that the barrier and all devices connected to it are operating properly. Use the (<, >) programming
buttons to open and close the barrier and the ESC button to stop it.
After powering up the system, the first maneuver is always the opening. In this phase, the barrier will not close, you need to wait for
a complete opening maneuver.
⚠
Immediately press the STOP button if the system manifests any anomalies, malfunctions, noises, strange vibrations or unexpected
behavior.