Page #11 background imageLoading...
Page #11 background image
2
1
5 ÷ 10
2
1
3
p. 11 - Manual FA01084-EN - 02/2018 - © CAME S.p.A. - "Translated original instructions"
Perforate the cable gland and fit it into its housing after threading the cables.
Lift the gearmotor by 5 to 10 mm from the plate by adjusting the threaded steel feet to allow any subsequent
adjustments between pinion and rack.
SETTING UP THE GEARMOTOR
Remove the gearmotor cover by turning the side bolts.
Place the gearmotor above the anchoring plate.
Careful! The electric cables must pass under the gearmotor case.