Movement Flasher (contact capacity:
24V – 25W max.)
Flashes during the opening and
closing phases.
Warning devices
1 ON – Encoder programming - activates the opening and closing end-stops adjustment procedure.
2 deactivated. Keep the dip-switch in OFF position
6.5 Adjustments
6.4 Function selection
/.
ON
OFF
Trimmer SLOW.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during different
phases, slow-down; if said force becomes greater than the adjusted level, the system intervenes by inverting the direction of
movement.
Trimmer A.C.T. = Adjusts the waiting time in the opening position. Once this time frame has lapsed, an automatic closing
procedure is performed. The waiting time may be adjusted to between 1 second and 120 seconds. Adjusting to the minimum
excludes the automatic closing function.
Trimmer CL.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during movement
closing; if said force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.
Trimmer OP.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during movement
opening; if said force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.