Photocells
Configure contact C1 or CX (NC), input for safety devices such as photocells.
See functions programming of input C1 or CX in:
- C1 reopening while closing. While the gate leaves are closing, opening the
contact causes the inversion of movement until they are completely open;
- CX partial stop, gate leaves stop if they are moving, triggering the automatic
closing time; if the automatic closing time is enabled);
- CX obstruction wait, gate leaves stop is they are moving. They resume
movement once the obstruction is removed.
If unused, contacts CX and C1 should be deactivated during programming.
Photocells safety connection (services test)
Reopening during closing photocells connection (NC contact) see
functions programming.
Safety devices
Photocells connection (NC contact), see the functions programming
section.
When programming, the operator needs to be in
stop mode.
When programming is finished, set all Dip-switches to OFF.
You can save up to 25 users.
Use the Dip-switch to select the function if the LED is
lit, the function is enabled. Whereas if the LED is off, the
function is disabled.
PROG
button
PRG LED
DIP-SWITCH
FUNCTIONS PROGRAMMING
Connecting the safety devices (i.e. the safety test)
At each opening and closing command, the control board checks the ecacy of
the safety devices (such as photocells).
Any anomalies will inhibit all commands.