Page 11 - Manual FA01359-EN - 03/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Power supply
1
Connecting to the mains (120/230 V AC - 50/60 Hz)
2
Power supply output for accessories
The output normally delivers 24 V AC.
The output delivers 24 V DC when the batteries start operating, if they are installed.
10 11 E 5
Maximum capacity of contacts
Device Output Power supply (V) Power (W)
Accessories 10 - 11 24 AC/DC 25
Flashing beacon 10 - E 24 AC/DC 25
Operator status warning
light
10 - 5 24 AC/DC 3
The sum of the power draw for the connected accessories must not exceed 50 W.
Gear motor with encoder
1
Gearmotor delayed while opening
2
Gearmotor delayed while closing
M1 N1 ENC1 M2 N2 ENC2
N
E
M
M
N
E