Scanner
®
2000 microEFM Section 2
Measuring Natural Gas via a Differential Pressure Meter
1RWH 7KLVVHFWLRQFRQWDLQVLQVWDOODWLRQJXLGHOLQHVIRURUL¿FHDQGFRQHPHWHUV,ILQVWDOOLQJWKH6FDQQHU
ZLWKDQDYHUDJLQJSLWRWWXEHPHWHUUHIHUWRPDQXIDFWXUHULQVWUXFWLRQVIRULQVWDOODWLRQ
%HVW3UDFWLFHVIRU2UL¿FHDQG&RQH0HWHU,QVWDOODWLRQ
7RHQVXUHPHDVXUHPHQWDFFXUDF\HQVXUHWKDWWKHPHWHUUXQFRPSOLHVZLWKWKHIROORZLQJ$*$DQG,62
JXLGHOLQHVDVDSSOLFDEOH
 'RQRWSODFHXQLWQHDUYHQWVRUEOHHGKROHVWKDWGLVFKDUJHFRUURVLYHYDSRUVRUJDVHV
 Consider the orientation of the meter run when determining the best position for mounting the Scanner

If the Scanner 2000 is mounted to a horizontal pipeline, make sure process connections are at the top
RIWKHOLQHDQGPRXQWWKH6FDQQHUDERYHWKHSUHVVXUHFRQQHFWLRQVDWWKHSLSH
If the Scanner 2000 is mounted to a vertical pipeline, install the sensor above the differential pressure
VRXUFHFRQQHFWLRQVRULQVWDOODFRQGHQVDWHGULSSRWWRSUHYHQWWKHDFFXPXODWLRQRIOLTXLGLQLQWHU-
FRQQHFWLQJWXEHV6ORSHDOOWXELQJXSZDUGDWOHDVWLQFKOLQHDUIRRWWRDYRLGOLTXLGHQWUDSPHQW
 0RXQWWKH6FDQQHUDVQHDUOHYHODVSRVVLEOHVXFKWKDWWKHRSHUDWRUKDVDFOHDUYLHZRIWKH/&'DQG
FDQDFFHVVWKHNH\SDGHDVLO\ZKHQWKHHQFORVXUHFRYHULVUHPRYHG7KHORFDWLRQVKRXOGEHDVIUHHIURP
YLEUDWLRQDVSRVVLEOH
 0DNHVXUHWKHKLJKSRUWRIWKHVHQVRUPDUNHG³+´LVFRQQHFWHGWRWKHXSVWUHDPVLGHRIWKHPHWHUUXQ
 )ORZVKRXOGUHPDLQVXEVRQLFWKURXJKRXWWKHPHDVXULQJVHFWLRQDQGVKRXOGEHVLQJOHSKDVH
 3LSHGLDPHWHUV'VKRXOGEHEHWZHHQLQPPDQGLQPPSHU,62RUJUHDWHUWKDQ
LQPPSHU$*$
 3LSH5H\QROGVQXPEHUVPXVWEHDERYH
 dRUL¿FHGLDPHWHUPXVWEHJUHDWHUWKDQRUHTXDOWRLQPP
 ȕGLDPHWHUUDWLRPXVWEHJUHDWHUWKDQRUHTXDOWRDQGOHVVWKDQRUHTXDOWR
 *DXJHOLQHVVKRXOGEHRIXQLIRUPLQWHUQDOGLDPHWHUDQGFRQVWUXFWHGRIPDWHULDOFRPSDWLEOHZLWKWKHÀXLG
EHLQJPHDVXUHG)RUPRVWDSSOLFDWLRQVWKHERUHVKRXOGEHQRVPDOOHUWKDQóLQPPDQGSUHIHUDEO\
LQPPLQGLDPHWHU7KHLQWHUQDOGLDPHWHUVKRXOGQRWH[FHHGLQPP,IKLJKWHPSHUDWXUH
ÀXLGVDUHOLNHO\WREHHQFRXQWHUHGPDNHVXUHWKHPHDVXULQJWXEHXVHGLVUDWHGIRUWKHDQWLFLSDWHGWHP-
SHUDWXUHUDQJH6HHDOVRWKHWHPSHUDWXUHZDUQLQJRQSDJH
 *DXJHOLQHOHQJWKVKRXOGEHPLQLPL]HGWRKHOSSUHYHQWSXOVDWLRQLQGXFHGHUURUV
 *DXJHOLQHVVKRXOGVORSHGRZQZDUGWRWKHPHWHUDWDPLQLPXPRIRQHLQFKSHUIRRW
 If gauge lines must slope in more than one direction, do not allow more than one bend and install a liquid
RUJDVWUDSDVDSSOLFDEOH$OLTXLGWUDSVKRXOGEHLQVWDOOHGDWWKHORZHVWSRLQWLQDJDVVHUYLFHLQVWDOODWLRQ
 *DXJHOLQHVVKRXOGEHVXSSRUWHGWRSUHYHQWVDJDQGYLEUDWLRQ
 Where pulsation is anticipated, full-port manifold valves with a nominal internal diameter consistent with
WKHJDXJHOLQHVDUHUHFRPPHQGHG