2.2.6 ALTERNATE POWER SOURCES
Batteries in the battery case are the normal source of power for the Survey Meter
and its accessories. Alternate power sources are available. They are:
1. Instead of the batteries, the Survey Meter can receive power from CV100
converter which is plugged into a 120 V ac outlet. With the batteries removed
from the battery case of the meter, this converter's output provides power to the
Meter via a connector that mates with the communication port.
2. Another converter module, this one for vehicular use, is also available. This
module operates on input of 12 to 24 V dc and provides the 9 V dc needed by
the Survey Meter. It connects to the Meter as described in step "1" above.
38