seconds in CBT). sending machine.
##104 TX RTN or PIN has been received. - Try a higher transmission level.
##106 RX The procedure signal has been expected for 6
seconds, but not received.
- Increase the transmission level of the
sending machine.
##107 RX Fallback is not available at the sending machine. - Increase the transmission level of the
sending machine.
##109 TX After DCS transmission, a signal other than DIS,
DTC, FTT, CFR, or CRP has been received, and
re-transmission of the procedure signal has been
attempted the specified number of times but
failed.
##111 TX / RX Memory error - Eliminate all the data, and register them
again.
##114 RX RTN has been received. - Increase the transmission level of the
sending machine.
##200 RX A carrier has not been detected for 5 seconds
during image reception.
- Increase the transmission level of the
sending machine.
##201 TX / RX DCN has been received in a method other than
the binary procedure.
- Set the other machine ready for
reception.
##204 TX DTC has been received even when there is no
sending data.
##220 TX / RX System error (main program hang-up) - Turn the machine off, and turn it on
again
- Modular board
- Logic board
##224 TX / RX An error has occurred in the procedure signal in
G3 transmission.
##226 TX / RX The stack pointer has shifted from the RAM area. - Turn the machine off, and turn it on
again.
##229 RX The recording area has been locked for 1 minute. - After the area is unlocked, print the
recorded image.
##232 TX The encoder control unit has malfunctioned. - Modular board
- Logic board
##237 RX The decoder control unit has malfunctioned. - Modular board
- Logic board
##238 RX The print control unit has malfunctioned. - Modular board
- Logic board
##261 TX / RX A system error has occurred between the modem
and the system control board.
- Modular board
- Logic board
##280 TX Re-transmission of the procedure signal has been
attempted the specified number of times, but
- Try a higher transmission level.