MAP1 Page 9 of 31
Installation Manual June 2018 • Rev. 1.6
3. The MAP1 allows for the control of up to 4 door combinations. Ensure that
adequate 12V DC power and current is available, especially when the same
power supply is used for the locks.
4. It is highly recommended to use a separate power supply for locks as they
require a high amount of current for proper operation.
Network Information:
1. The MAP1 Controller is set to acquire an IP address automatically (DHCP).
However, it can be optionally set to a static IP address or reset if necessary. See
Appendix section for more information.
Mechanical Information:
1. The MAP1 has 2 horizontal mounting flanges, which should be used to
attach the product to a stable surface.
2. If required the MAP1 may be mounted inside of a lockable enclosure such as
the CA-SLBOX or CA-H1000ENCL if access is to be limited to the external
connections.
3. If a Lockable external enclosure is used and a Tamper switch is available as in
the CA-SLBOX or CA-H1000ENCL, the MAP1 has a Panel Tamper input
connection available. Connecting the Tamper switch, See figure 14, to this
input will produce an Alarm when opening and closing the enclosure. This
Alarm is sent to the Host computer.