-61-
Troubleshooting
6
Area
M a l f u n c t i o n
P o s s i b l e C a u s e Corrective Measure R e f .
B r a k e
Brake does not work
well.
Not properly adjusted. →Adjust. Page 47
Brake is wet with
water.
→Apply brake a few
times to dry.
Other (other than the
above).
→Please contact
your CANYCOM
representative.
T r a c k
Track does not move
smoothly.
Not properly adjusted. →Adjust. Page 41
Other (other than the
above).
→Please contact
your CANYCOM
representative.
S a f e t y
D e v i c e s
Lamp does not light.
Blown bulb. →Replace.
Blown fuse. →Replace. Page 55
Other (other than the
above).
→Please contact
your CANYCOM
representative.
Horn does not work.
Blown fuse. →Replace. Page 55
Other (other than the
above).
→Please contact
your CANYCOM
representative.
Hydraulic
( D u m p )
s y s t e m
Dump does not work.
Insufcient or
deteriorated hydraulic
uid.
→Add or change uid. Page 42
Loose hydraulics belt. →Adjust. Page 52
Other (other than the
above).
→Please contact
your CANYCOM
representative.