EasyManua.ls Logo

Caple CE1122SS - Timing

Caple CE1122SS
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction manual CE1122
Please keep this instruction manual for future reference
20
TIMING
- As a result of the new EU65 “Energy label” and EU66 “ Ecodesign” regulations
issued by the European Commission, which came into force as from January 1st,
2015 , our products have been adapted to comply with these new requirements.
All of the models complying with the energy label requirements, are equipped
with new electronics including a timer device for extraction speeds control, when
the air capacity exceeds 650m³/h. Internal motor models, with maximum air
capacity higher than 650m³/h, are equipped with a timer device that automatically
switches the extraction speed from 4th to 3rd speed, after 5 minutes operation
- External motor models are equipped with remote motors that , as for internal
motor versions, include a timer device that switches down the extraction speed
when it exceeds 650 m³/h. (See External Motors Instructions ). Remote motors,
whose air capacity exceeds 650m³/h at both 4th and 3rd speed, will have the
following by default timer control functions:
- The extraction speed is automatically switched from 4th to 2nd speed, after 6
minutes operation. If the appliance is working at 3rd speed, it is automatically
switched to 2nd speed, after 7 minutes operation. Operation speeds can also be
changed during operation. The energy consumption of the appliance in standby
mode is lower than 0.5W.
CE1122SS/WH_Instruction manual.indd 20 22/03/2018 10:53