EasyManua.ls Logo

Caple CE1122SS - Installation

Caple CE1122SS
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction manual CE1122
Please keep this instruction manual for future reference
8
INSTALLATION
NOTE: Two people are needed for the installation of this product.
It is possible to open the glass/steel panels, which cover the grease filters, by slightly
pulling the panel on a side, as shown on fig.1 In order to allow the hood to perform
correctly, it is recommended to install the appliance at a distance of 2000 - 2100
mm from the floor. Before starting the appliance installation, please check that
all components are not damaged, in such a case contact your retailer and do not
carry out the installation. Furthermore, please read carefully all of the following
installation instructions.
- For the best performance we recommend an exhausting pipe with a maximum
length not exceeding 5 meters.
- Limit the number of elbows in the piping, since each elbow reduces the air
capacity of 1 linear meter. (Eg. if you use 2 x 90° elbows, the length of piping
should not exceed 3 meters).
- Avoid abrupt direction changes.
- Use a 150 mm constant diameter pipe for the whole length.
- Use ducting approved by the local standards inforce.
NOTE: For more information on venting, please see our ‘Extraction & Ventilation
guide’ available on our website www.caple.co.uk.
CE1122SS/WH_Instruction manual.indd 8 22/03/2018 10:53