  • H
    Heather HarrellSep 9, 2025
    What to do if the Cardinal 225 indicator is attempting to display a number greater than seven digits?
    • R
      robinsonstephenSep 10, 2025
      If the Cardinal Scales indicator attempts to display a number exceeding the digit limit, this may indicate miscalibration. Return to Gross Weight mode and review the Tare value.
  • V
    vweberSep 8, 2025
    What to do if motion is present when trying to power up, print, zero or perform a push button tare function on Cardinal 225 Scales?
    • M
      Madison JonesSep 8, 2025
      If there is motion present while attempting to power up, print, zero, or perform a push-button tare function on Cardinal Scales, wait for a stable weight display (STABLE symbol on) before performing any of these operations.
  • T
    Tracy MccormickSep 7, 2025
    What to do if EEPROM checksum failure occurs on Cardinal 225 Scales?
    • J
      James WilsonSep 7, 2025
      If an EEPROM checksum failure occurs, indicating improper stored calibration data, recalibrate the Cardinal Scales with a calibrated test weight.
  • C
    carolinesimpsonAug 22, 2025
    What to do if Cardinal Accessories scale shows OVERCAP?
    • M
      Mariah LopezAug 22, 2025
      If your Cardinal Accessories scale displays 'OVERCAP', it means the load on the scale exceeds its capacity, possibly due to miscalibration. Remove the excess weight from the scale. If the problem persists, it's advisable to consult a scale service provider for recalibration.
  • P
    Peter McintoshSep 4, 2025
    What to do if the load cell input is below the allowed range of the Cardinal 225 Scales indicator?
    • R
      Richard ChambersSep 4, 2025
      If the load cell input is below the allowed range, this may indicate a load cell or circuit failure. Check for improper load cell wiring and ensure the output is between 1 to 40mV.
  • S
    Sean LopezSep 3, 2025
    What to do if the load cell input is above the allowed range of the Cardinal 225 Scales indicator?
    • D
      Dennis ThomasSep 3, 2025
      If the load cell input exceeds the indicator's allowed range, it may be caused by load cell or circuit failure. Check for improper load cell wiring, excessive load, and verify the output is between 1 to 40mV.
  • B
    barrysandersSep 2, 2025
    Why is Cardinal Scales displaying incorrect weight?
    • D
      Dawn MeadowsSep 2, 2025
      Several factors can cause Cardinal Scales to display an incorrect weight: * Verify the indicator has been calibrated. * Ensure the scale platform isn't touching any adjacent objects. * Check the load cell connector wiring. * If using four-wire load cells, ensure the sense lead jumper (J9) is installed. * Confirm proper operating procedures are being followed.
  • L
    Lynn JohnsonSep 1, 2025
    What to do if Cardinal Scales display does not turn on?
    • P
      Paul MartinSep 1, 2025
      If the Cardinal Scales display doesn't turn on: * Ensure the AC power cord is fully inserted into the wall receptacle. * Check the wall receptacle for proper AC power by testing with another electrical appliance. * Check the circuit breaker. * Consider if there has been a power failure.
  • H
    hillalexisAug 31, 2025
    Why is the Cardinal 225 load exceeding capacity?
    • B
      Barbara GreenAug 31, 2025
      The Cardinal Scales may display this issue due to miscalibration. Remove the excess load from the scale platform. Consult your scale service provider regarding recalibration.
  • D
    Dr. David GreenAug 29, 2025
    How to fix CAL LOST CONFIG REQUIRED on Cardinal Accessories?
    • S
      slewisAug 29, 2025
      The 'CAL LOST CONFIG REQUIRED SCALE X' error on your Cardinal Accessories indicates an EEPROM checksum failure, meaning the stored calibration data is improper. You will need to recalibrate the scale using a calibrated test weight.

Summary

INSTALLATION

Logic Level Output

Explains logic level outputs for controlling peripheral devices based on weight limits.

Output Cable Installation

Step-by-step instructions for routing and connecting output cables to the indicator.

AC Output Relay Board(s)

Details AC output relay boards (RB4-ACOUT, RB8-ACOUT) for external junction boxes.

OPTICALLY ISOLATED REMOTE INPUTS

Input Cable Installation

Procedure for installing cables for remote inputs to the indicator's terminal block P17.

AC Input Relay Board(s)

Describes AC input relay boards for 115 VAC and 230 VAC versions, supporting multiple inputs.

MAIN PC BOARD OVERVIEW

PC Board Connectors

Identifies key connectors on the main PC board, such as P15, P16, P17, and P18.

MAIN PC BOARD JUMPERS

Remote Output Jumpers (J4, J5)

Configures active remote output jumpers for sourcing 5 VDC or isolated outputs.

Remote Input Jumper (J6)

Configures the remote input jumper for sourcing 5 VDC or isolated inputs.

Auto-On and Test Jumpers (J1, J2)

Jumpers for enabling automatic power-on and activating the backlight test.

Other Jumpers (J3, J7-J10)

Details jumpers for excitation, sense leads, dead load boost, and ground connection.

RE-INSTALLING THE REAR PANEL

SETUP

Accessing Setup Menus

Procedure to navigate to the Check Weigher setup menus.

OUTPUTS Parameter Configuration

Setting the number of check weigher outputs (3-zone or 5-zone comparison).

AUTO PRINT Parameter

Configuring the automatic print feature based on weight stability and range.

OPERATION

Relay Control Output Modes

Explains relay outputs for 3-zone (OUTPUTS=3) and 5-zone (OUTPUTS=5) comparisons.

Setting 3-Zone Presets

Procedure to enter UNDER and OVER preset values for 3-zone operation.

Setting 5-Zone Presets

Procedure to enter UNDER, LOW OK, HIGH OK, and OVER presets for 5-zone operation.

NOTES

Cardinal 225 Specifications

General IconGeneral
Auto Shut-offYes
Tare FunctionYes
Capacity225 lbs
Graduation0.1 lb
Power SourceBattery (included)