F YOU SELECTED LEVEL 3 FILTERING THEN:
BREAK RANGE
Press to show the current filter setting. Press
through to enter the new filter value (1 to 16). The
larger the number, the greater the effect. Then press
to save it or to retain the current setting. Filter is the number of weigh samples
that will be averaged before being displayed. If F=6, the weight value placed in
the display will be the average of the last six (6) consecutive weigh samples.
Press to show the current break range setting. Press
through to enter the new break range (1 to 64).
The larger the number the greater the weight change
required to break out of the filtering. Press to save the new value or to save
the current displayed value of break range.
F=
br=
9
ENTER
ENTER
0
0
9
ENTER
ENTER
Press to show the current setting. Press through
to enter the new value for the motion range. Weight
changes greater than this number of divisions will indicate
motion. Press to save the new setting or to save the current motion range
setting.
UnSt=
1
9
ENTER
ENTER
MOTION RANGE
BLANK ON MOTION
SAMPLE RATE
AUTOMATIC SHUTOFF (Battery Operation Only - see SETUP REVIEW)
Press to show the current setting. Press or
to enter the new setting. Then press to save it
or to save the current setting.
no = Do Not Blank Display On Motion YES = Blank Display On Motion
Press to show the current sample rate. Press
through to enter the new Sample Rate (1 to 12
samples per second). Then press to save it or to save
the current setting.
Press to show the current setting. Press through
to enter the new setting. Then press to save it
or to save the current setting.
0 = Disable Automatic Shutoff 1 through 9 - Number of Minutes of
Inactivity (No Motion)
Before Power Off
0
ENTER
1
ENTER
bL=
Sr=
ASH=
ENTER
ENTER
ENTER
9
ENTER
0
0
9