19
SLEEP MODE (Battery Operation Only - see SETUP REVIEW)
PRESET WEIGHT COMPARATORS
Press to show the current setting. Press through
to enter the new setting. Then press to save it
or to save the current setting. Weight applied to scale, or
key pressed, will enable system operation.
0 = Disable Sleep Mode 1 through 9 - Number of Minutes at
Zero (Zero Indicator On)
Before Going to Sleep
Press to show the number of presets. Press
through to enter the new number of preset weight
comparators. Then press to save it or to save the
current setting.
PSEtS=
SLP=
ENTER
0
ENTER
9
ENTER
ENTER
8
0
PWC OUTPUT STATE: UNDER PRESET WEIGHT VALUE
TRUCK STORAGE
PUSH BUTTON TARE
If 1 or more presets were entered, this prompt will appear
for each preset entered - the 1 position will indicate the
PWC number. Press to show the current setting for
the PWC output. on indicates that the PWC output is high (the PWC relay is on)
at weights under or less than the preset weight and will switch to off (the PWC
relay is off) at the preset weight and above. oFF indicates that the PWC output is
low (the PWC relay is off) at weights under the preset weight and will switch to on
(the PWC relay is on) at the preset weight and above. Press the key for off
and the key for on.
Press to show the current setting. Press or
to enter the new setting. Press to save the
new setting or to save the current setting. This question will
not appear if Dual Ranging was selected and the decimal point setting for the
High Interval differs from the decimal point setting for the Low Interval.
no = No Truck Storage YES= Truck Storage
Press to show the current setting. Press or
to enter the new setting. Then press to save it or to
save the current setting.
no = Numeric Tare YES= Push Button Tare Only
0
1
ENTER9
Undrl=
trSto=
PbtAr=
ENTER
ENTER
0
ENTER
0 1ENTER