Fig.4.b
Note: MPXone is compatible with Carel and Modbus® supervisor networks. The type of protocol is set
via parameter H3
H3: BMS serial protocol
MPXone is compatible with Carel and Modbus supervisor networks, which can be selected using
parameter H3.
Code Description Def Min Max UOM User
User
terminal
H3
BMS serial port protocol
0/1 = Carel slave/Modbus slave
1 0 1 - S NO
/P1: Type of probe, group 1 (S1, S2, S3)
This is used to select the type of temperature probe to be used for inputs S1, S2 and S3.
Code Description Def Min Max UOM User
User
terminal
/P1
Type of probe, group 1 (S1, S2, S3)
0 = PT1000 Standard Range –50T150 °C
1 = NTC Standard Range –50T90°C
1 0 1 - S NO
34|4. Initial configuration
MPXone +0300086EN rel. 1.0 04.09.2018