31
13 - LIST OF CONTROL PARAMETERS WITH "ACCESS LEVEL 1"
Screen Parameter Description of the parameter Value Min. Max. UOM Type R/W
Add.
BMS
P01 PLAN_ADDRESS Address of the unit in the pLAN local network 0 0 0 --- Integer R
P01 HORA
Clock: hour
0 0 0 h Integer R 48
P01 MINUTO
Clock: minute
0 0 0 min Integer R 47
P01 MODO_VENT
VENTILATION operating mode
0 0 1 --- Digital R 236
P01 MODO_FRIO
COOLING operating mode
0 0 1 --- Digital R 14
P01 GLOBAL_ALARM
Signal of active alarms
0 0 1 --- Digital R 26
P01 TEMP_INT
Indoor temperature for regulation of the unit
0.0 -99.9 0.0 °C Analog. R 291
P01 TEMP_EXT
Temperature of the outdoor air
0.0 -99.9 0.0 °C Analog. R 2
P01 HUM_INT
Indoor relative humidity for regulation of the unit
0.0 0.0 0.0 %rH Analog. R 5
P01 ESTADO_EQUIPO
Unit status (ON, OFF, remote OFF, OFF by phase)
0 0 0 --- Integer R
P01 EN_FASE_HOR_NUEVA
Indication of unit switch-on by schedule programming
0 0 1 --- Digital R
P01 DESHUMIDIFICA
Indication of active dehumidifi er
0 0 1 --- Digital R 304
P01 HUMIDIFICA
Indication of active humidifi er
0 0 1 --- Digital R 22
P01 ON_COMPENSACION
Indication of active compensation
0 0 1 --- Digital R
P01 ON_DESESCARCHE
Indication of active defrosting
0 0 1 --- Digital R 183
P01 ON_FREECOOL
Indication of active free-cooling
0 0 1 --- Digital R 184
P01 ON_FREEHEAT
Indication of active free-heating
0 0 1 --- Digital R 185
P01 LAMP_COMPRESOR
Indication of compressors in operation
0 0 1 --- Digital R
P01 LAMP_VINT
Indication of supply fans in operation
0 0 1 --- Digital R
P01 LAMP_RESISTENCIA
Indication of electrical heaters in operation
0 0 1 --- Digital R
P01 ON_LIMITE_TEMP_IMPULSION
Indication of unit in operation with limit of supply temperature
0 0 1 --- Digital R 238
P02 HORA
Clock: hour
0 0 0 h Integer R 48
P02 MINUTO
Clock: minute
0 0 0 min Integer R 47
P02 DIA
Clock: day
0 0 0 day Integer R 49
P02 MES
Clock: month
0 0 0 month Integer R 50
P02 ANO
Clock: year
0 0 0 year Integer R 51
P02 MODO_FRIO
VENTILATION operating mode
0 0 1 --- Digital R
P02 MODO_VENT
COOLING operating mode
0 0 1 --- Digital R 236
P02 GLOBAL_ALARM
Signal of active alarms
0 0 1 --- Digital R 26
P02 SET_TEMP_DISPLAY
Active setpoint temperature
0.0 0.0 0.0 °C Analog. R
P02 ESTADO_EQUIPO
ON/OF unit status
0 0 0 --- Integer R
P02 EN_FASE_HOR_NUEVA
Indication of unit switch-on by schedule programming
0 0 1 --- Digital R
P02 DESHUMIDIFICA
Indication of active dehumidifi er
0 0 1 --- Digital R
P02 HUMIDIFICA
Indication of active humidifi er
0 0 1 --- Digital R 22
P02 ON_COMPENSACION
Indication of active compensation
0 0 1 --- Digital R
P02 ON_DESESCARCHE
Indication of active defrosting
0 0 1 --- Digital R 183
P02 ON_FREECOOL
Indication of active free-cooling
0 0 1 --- Digital R 184
P02 ON_FREEHEAT
Indication of active free-heating
0 0 1 --- Digital R 185
P02 LAMP_COMPRESOR
Indication of compressors in operation
0 0 1 --- Digital R
P02 LAMP_VINT
Indication of supply fans in operation
0 0 1 --- Digital R
P02 LAMP_RESISTENCIA
Indication of electrical heaters in operation
0 0 1 --- Digital R
P02 ON_LIMITE_TEMP_IMPULSION
Indication of unit in operation with limit of supply temperature
0 0 1 --- Digital R 238
P03 PLAN_ADDRESS Address of the unit in the pLAN local network 0 0 0 --- Integer R
P03 HAB_SUPERVISION Enabling the supervision serial card (optional) 1 0 1 --- Digital R 50
P03 TIPO_PROT_COM Supervision protocol (Carel, Modbus) 1 0 0 --- Integer R 227
P03 BMS_ADDRESS Address of the unit in the supervision network 1 0 0 --- Integer R 228
P03 BAUD_RATE Bits rate (0=1200, 1=2400, 2=4800, 3=9600, 4=19200, 5=38400) 4 0 4 --- Integer R 229
P03 Stop_bits_Number_MB
Number of stop bits for the MODBUS protocol (0 = 2 stop bits, 1= 1 stop bit)
0 0 1 --- Digital R 282
P03 Parity_Type_MB
Type of parity (no parity, odd or even)
0 0 2 --- Integer R 230
P04 MODELO_EQUIPO
Unit model
0 0 99 --- Integer R 58
P04 INFO_EQUIPO_1
Unit information: air-air, cooling-only, reversible
1 0 9 --- Integer R 191
P04 INFO_EQUIPO_2
Unit information: compressors-circuits (0,2c-1c,4c-2c) + recovery
1 0 99 --- Integer R 192
P04 UNICO_VOL_AIRE_EXT_CIRC_2
Selection of single-volume of outdoor air in 2-circuits units
0 0 1 --- Digital R
P04 TIPO_VENT_EXT
Type of outdoor fan (3= 2 speeds axial fan; 4= electronic axial fan or plug-fan)
4 1 4 --- Integer R 1
P04 INFO_EQUIPO_3
Unit information: with electrical heaters - gas burner/boiler - hot water coil
1 0 9 --- Integer R 193
P04 TIPO_REFRIGERANTE
Type of refrigerant (4=R410A, 5=R-454B)
4 0 5 --- Integer R 43
P04 NUM_WO_DIG_1
Work order number of the unit (digit 1)
0 0 9 --- Analog. R 185
P04 NUM_WO_DIG_2 Work order number of the unit (digit 2) 0 0 9 --- Analog.
R
186
Parameters of “Unit Status”
MODES
F
Important: All parameters of level “1” are visible to the fi nal user without any password. Parameters with levels of access “2” and “3” are