59SC2A
The
opening
shall
commence
within
12
in.
(300
mm)
of
the
ceiling.
Appliances
in
the
space
shall
have
clearances
of
at
least
1
in.
(25
mm)
from
the
sides
and
back
and
6
in.
(150
mm)
from
the
front.
The
opening
shall
directly
communicate
with
the
outdoors
or
shall
communicate
through
a
vertical
or
horizontal
duct
to
the
outdoors
or
spaces
(crawl
or
attic)
that
freely
communicate
with
the
outdoors.
Indoor
Combustion
Air©
NFPA
&
AGA
Standard
and
Known-Air-Infiltration
Rate
Methods
Indoor
air
is
permitted
for
combustion,
ventilation,
and
dilution,
if
the
Standard
or
Known-Air-Infiltration
Method
is
used.
CA
UA
Le:
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury
or
death.
Many
homes
require
air
to
be
supplied
from
outdoors
for
furnace
combustion,
ventilation,
and
dilution
of
flue
gases.
The
furnace
combustion
air
supply
must
be
provided
in
accordance
with
this
instruction
manual.
Standard
Method
1.
The
space
has
no
less
volume
than
50
cubic
feet
per
1,000
Btuh
of
the
maximum
input
ratings
for
all
gas
appliances
installed
in
the
space
and
2.
The
air
infiltration
rate
is
not
known
to
be
less
than
0.40
air
changes
per
hour
(ACH).
The
Known
Air
Infiltration
Rate
Method
shall
be
used,
if
the
infiltration
rate
is
known
to
be:
1.
Less
than
0.40
ACH
and
2.
Equal
to
or
greater
than
0.10
ACH
Infiltration
rates
greater
than
0.60
ACH
shail
not
be
used.
The
minimum
required
volume
of
the
space
varies
with
the
number
of
ACH
and
shall
be
determined
per
Table
4
or
Equations
1
and
2.
Determine
the
minimum
required
volume
for
each
appliance
in
the
space
and add
the
volumes
together
to
get the
total
minimum
required
volume
for
the
space.
Table
4
-
Minimum
Space
Volumes
were
determined
by
using
the
following
equations from
the
current
edition
of
the
National
Fuel
Gas
Code
ANSI
2223.1/NFPA
54,
9.3.2.2:
1.
For
other
than
fan-assisted
appliances,
such
as
a
draft
hood-equipped
water
heater:
—_
21ft
|
other
Vol
=
21TY
|
____other__
ee
other
AGH
(7000
Btu/hr
A04002
2.
For
fan-assisted
appliances
such
as
this
furnace:
3
|
Volume
=
15ft
fan
Fan
=
=ACH
|1000
Btu/hr
A04008
If:
lother
=
combined
input
of
all
other
than
fan-assisted
appliances
in
Btuh/hr
Ifan
=
combined
input
of
all
fan-assisted
appliances
in
Btuh/hr
ACH
=
air
changes
per
hour
(ACH
shail
not
exceed
0.60.)
The
following
requirements
apply
to
the
Standard
Method
and
to
the
Known
Air
Infiltration
Rate
Method.
1.
Adjoining
rooms
can
be
considered
part
of
a
space
if:
a.
There
are
no
closeable
doors
between
rooms.
b.
Combining
spaces
on
same
floor
level.
Each
opening
shail
have
free
area
of
at
least
1
in.2/1,000
Btuh
(2,000
mm2/kW)
of
the
total
input
rating
of
all
gas
appliances
in
the
space,
but
not
less
than
100
in.?
(0.06
m?).
One
opening
shall
commence
within
12
in.
(300
mm)
of
the
ceiling
and
the
second
opening
shall
commence
within
12
in.
(300
mm)
of
the
floor.
The
minimum
dimension
of
air
openings
shall
be
at
least
3
in.
(80
mm).
See
Fig.
7.
c.
Combining
space
on
different
floor
levels.
The
volumes
of
spaces
on
different
floor
levels
shall
be
considered
as
com-
municating
spaces
if
connected
by
one
or
more
permanent
openings
in
doors
or
floors
having
free
area
of
at
least
2
in.2/1,000
Btuh
(4,400
mm2/kW)
of
total
input
rating
of
all
gas
appliances.
bo
.
An
attic
or
crawlspace
may
be
considered
a
space
that
freely
communicates
with
the
outdoors
provided
there
are
ad-
equate
permanent
ventilation
openings
directly
to
outdoors
having
free
area
of
at
least
1-in.7/4,000
Btuh
of
total
input
rating
for
all
gas
appliances
in
the
space.
3.
In
spaces
that
use
the
Indoor
Combustion
Air
Method,
in-
filtration
should
be
adequate
to
provide
air
for
combustion,
permanent
ventilation
and
dilution
of
flue
gases.
However,
in
buildings
with
unusually
tight
construction,
additional
air
MUST
be
provided
using
the
methods
described
in
the
Outdoor
Combustion
Air
Method
section.
4.
Unusually
tight
construction
is
defined
as
Construction
with:
a.
Walls
and
ceilings
exposed
to
the
outdoors
have
a
continu-
ous,
sealed
vapor
barrier.
Openings
are
gasketed
or
sealed
and
b.
Doors
and
openable
windows
are
weatherstripped
and
c.
Other
openings
are
caulked
or
sealed.
These
include
joints
around
window
and
door
frames,
between
sole
plates
and
floors,
between
wail-ceiling
joints,
between
wail
panels,
at
penetrations
for
plumbing,
electrical
and
gas
lines,
etc.
Combination
of
Indoor
and
Outdoor
Air
1.
Indoor
openings
shail
comply
with
the
Indeor
Combus-
tion
Air
Method
below
and,
2.
Outdoor
openings
shail
be
located
as
required
in
the
Out-
door
Combustion
Air
Method
mentioned
previously
and,
3.
Outdoor
openings
shail
be
sized
as
follows:
a.
Calculate
the
Ratio
of
ail
Indoor
Space
volume
divided
by
required
volume
for
Indoor
Combustion
Air
Method
be-
low.
b.
Outdoor
opening
size
reduction
Factor
is
1
minus
the
Ra-
tio
in
a.
above.
c.
Minimum
size
of
Outdoor
openings
shall
be
the
size
re-
quired
in
Outdoor
Combustion
Air
Method
above
multi-
plied by
reduction
Factor
in
b.
above.
The
minimum
di-
mension
of
air
openings
shall
be
not
less
than
3
in.
(80
mm).
10