Carrier 59SC2A - Maximum Equivalent Vent Length; Deductions from Maximum Equivalent Vent Length

Carrier 59SC2A
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
15
—-
Maximum
Equivalent
Vent
Length
-
Ft.
(VM)
0
to
4500
Ft.
(0
to
1370
M)
Altitude
NOTE:
Maximum
Equivalent
Vent
Length
(MEVL)
includes
standard
and
concentric
vent
termination
and
does
NOT
include
elbows.
Use
Table
16
-
Deductions
from
Maximum
Equivalent
Vent
Length
to
determine
allowable
vent
length
for
each
application.
DIRECT
VENT
(2-PIPE)
AND
NON-DIRECT
VENT
(1-PIPE)
Altitude
BTU/Hr
FT
(M)
0
to
2000
(0
to
610)
2001
to
3000
(610
to
914)
59SC2A
3001
to
4000
(914
to
1219)
4001
to
4500
(1219
to
1370)
See
Table
17
for
altitudes
over
4500
ft.
(1870
M)
ELBOW
CONFIGURATIONS
VENT
TERMINAL
CONFIGURATIONS
&
ey
:
Concentric
Long
Medium
Mitered
(FP
AW
oo
(((
{
Jp
7
CO
LY
Standard
\
A11580
Table
16
Deductions
from
Maximum
Equivalent
Vent
Length
-
Ft.
(M)
Pipe
Diameter
(in):
4-1/2
2
2-1/2
3
4
Mitered
902°
Elbow
8
(2.4)
8
(2.4)
8
(2.4)
8
(2.4)
8
(2.4)
Medium
Radius
902
Elbow
5
(1.5)
5
(1.5)
5
(1.5)
5
(1.5)
5
(1.5)
Long
Radius
902
Elbow
3
(0.9)
3
(0.9)
3
(0.9)
3
(0.9)
3
(0.9)
Mitered
45°
Elbow
4
(1.2)
4
(1.2)
4
(1.2)
4
(1.2)
4
(1.2)
Medium
Radius
452
Elbow
25
(0.8)
25
(0.8)
25
(0.8)
25
(0.8)
25
(0.8)
Long
Radius
45°
Elbow
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
Tee
16
(4.9)
16
(4.9)
16
(4.9)
16
(4.9)
16
(4.9)
Concentric
Vent
Termination
(0.0)
(0.0)
Standard
Vent
Termination
(0.0) (0.0)
47