59SC2A
Table
9
Air
Delivery
-
CFM
(With
Filter)
UNIT
RETURN-AIR
SPEED
EXTERNAL
STATIC
PRESSURE
(IN.W.C.)
SIZE
CONNECTION
TAPS
2
0.2 0.3 0.4
0.5
0.6
Black
1055 1010
960 905 850
Yellow
915 875 830 790 740
Blue
795 765 730 695 655
Red
710 680 655 625 595
Black
1295 1245 1190 1130 1065
Yellow
1010
980 945 910 865
Blue
825 810 785 755 710
SIDE/BOTTOM
SIDE/BOTTOM
Black
1615 1550 1485 1420 1345
Yellow
1320 1295 1260 1215 1165
SIDE/BOTTOM
Orange
1045 1035 1015
995 960
Blue
980 975 950 930 900
Black
1810 1740 1670 1600 1525
Yellow
1495 1460 1415 1365 1305
SIDE/BOTTOM
Orange
1355 1330 1300 1260 1210
Blue
1040 1030 1010
985 960
Black
2250
2160 2065
1970 1880
Yellow
2030
1960 1885 1805 1720
Orange
1810 1765 1725 1665 1590
Blue
1685 1660 1615 1570 1510
Red
1410 1385 1365 1335 1290
Black
1705 1660 1605 1545 1475
Blue
1510 1470 1430 1380 1320
Yellow
1255 1220 1180 1130 1075
BOTTOM
or
TWO-SIDES
3:4
SIDE/BOTTOM
Black
2330
2245 2155 2065
1965
Yellow
2075
2010
1945 1865 1785
Orange
1815 1785 1740 1685 1625
Blue
1680 1655 1620 1580 1530
Red
1405 1390 1370 1345 1305
Black
2360
2295 2215 2105
1975
Blue
2245 2185
2090
2005
1855
Yellow
1780 1750 1705 1650 1595
BOTTOM
or
TWO-SIDES
3:4
BOTTOM
or
TWO-SIDES
3:4
NOTE:
1.
A
filter
is
required
for
each
return—air
inlet.
Airflow
performance
includes
a
3/4—in.
(19
mm)
washable
filter
media
such
as
contained
in
a
factory
—author-
ized
accessory
filter
rack.
See
accessory
list.
To
determine
airflow
performance
without
this
filter,
assume
an
additional
0.1
in.
w.c..
available
external
static
pressure.
2.
Blower
speed
taps
are not
always
in
the
same
order.
Factory
default
blower
connections
are
as
follows:
a.
Heating
airflow
BLUE
(also
used
for
Continuous
Fan)
b.
Cooling
airflow
BLACK
(enabled
when
the
Y
terminal
is
energized)
ADJUST
THE
BLOWER
SPEED
TAPS
AS
NECESSARY
FOR THE
PROPER
AIR
TEMPERATURE
RISE
FOR
EACH
INSTALLATION.
3.
Airflows
over
1800
CFM
require
bottom
return,
two—side
return,
or
bottom
and
side
return.
A
minimum
filter
size
of
20”
x
25”
(508
x
635
mm)
is
required.
.
For
upflow
applications,
air
entering
from
one
side
into
both
the
side
of
the
furnace
and
a
return
air
base
counts
as
a
side
and
bottom
return.
5.
Highlighted
areas
indicate
that
this
airflow
range
is
beyond
the
range
allowed
for
heating.
THESE
AIRFLOW
RANGES
MAY
ONLY
BE
USED
FOR
COOL-
ING.
fp